Automatic graph-based method for localization of cochlear implant electrode arrays in clinical CT with sub-voxel accuracy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel perfusion-based method for cochlear implant electrode insertion.

A cochlear implant (CI) restores partial hearing to profoundly deaf individuals. CI electrodes are inserted manually in the cochlea and surgeons rely on tactile feedback from the implant to determine when to stop the insertion. This manual insertion method results in a large degree of variability in surgical outcomes and intra-cochlear trauma. Additionally, implants often span only the basal tu...

متن کامل

A cochlear implant electrode.

This study has shown that an electrode array can be passed along the hold length of the cochlea if it is inserted through and opening in the scala tympani of the apical turn. The electrode must have the appropriate mechanical properties and some of these were stiffness and extensibility. The electrode and operative approach should be helpful in stimulating the terminal auditory nerve fibres on ...

متن کامل

Electrode interaction in cochlear implant recipients: comparison of straight and contour electrode arrays.

The degree of overlap among cochlear nerve fibers stimulated by different electrodes results in electrode interaction, which has been shown to have a significantly deleterious effect on speech recognition performance in multi-electrode cochlear implant users. The Nucleus CI24R(CS) Contour array, which lies substantially closer to the modiolus than the CI24M straight array, is expected to exhibi...

متن کامل

Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan

Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...

متن کامل

Microminiature molding techniques for cochlear electrode arrays.

We provide a general method for producing a variety of small, complex electrode arrays based on injection molds produced using computer-aided drafting and machining (CAD-CAM) procedures and a novel method for connecting to the very fine electrical leads associated with the individual contacts of such arrays. Cat-sized cochlear electrode arrays with up to eight contacts were built according to t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Medical Image Analysis

سال: 2019

ISSN: 1361-8415

DOI: 10.1016/j.media.2018.11.005