Automatic Generation Control of Two Area Thermal Power System with PI Controllers Using State Space Approach
نویسندگان
چکیده
منابع مشابه
Load frequency control of two-area interconnected power system using fuzzy logic control approach
Power systems are composed of power units that are constantly connected to each other and the electric power flux is constantly moving between them. All systems must be implemented in such a way that not only under normal conditions but also unwanted inputs or disturbances, are applied. It also remains stable or returns to a stable name at the earliest possible time. The fundamental factors...
متن کاملDesign of Fuzzy Logic Based PI Controller for DFIG-based Wind Farm Aimed at Automatic Generation Control in an Interconnected Two Area Power System
This paper addresses the design procedure of a fuzzy logic-based adaptive approach for DFIGs to enhance automatic generation control (AGC) capabilities and provide better dynamic responses in multi-area power systems. In doing so, a proportional-integral (PI) controller is employed in DFIG structure to control the governor speed of wind turbine. At the first stage, the adjustable parameters of ...
متن کاملAutomatic Generation Control Using LQR based PI Controller for Multi Area Interconnected Power System
The continuous time Linear Quadratic Regulator (LQR) theory has been implemented in the present work for the design of optimal Proportional Integral(PI) controller for the frequency response enhancement of multi area interconnected power system . The PI controller gains as proportional gain (Kp) and integral gain (Ki) are formulated as the optimal state-feedback gains, corresponding to the stan...
متن کاملHybrid Neuro Fuzzy Approach for Automatic Generation Control of Two -Area Interconnected Power System
The main objective of Automatic Generation Control (AGC) is to balance the total system generation against system load losses so that the desired frequency and power interchange with neighboring systems is maintained. Any mismatch between generation and demand causes the system frequency to deviate from its nominal value. Thus high frequency deviation may lead to system collapse. This necessita...
متن کاملSampled Data Automatic Generation Control of a Two Area Reheat Thermal System with Modified Area Control Error
This paper deals with Automatic Generation Control (AGC) of a two area reheat thermal system with modified area control error (ACEM) considering operation of the system in the continuous-mode and that of the controller in the discrete mode. ACEM is the weighted sum of frequency deviation, tie-power deviation and inadvertent interchange energy. Studies show that the AGC-strategy based on ACEM pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Electrical and Electronics Engineering
سال: 2020
ISSN: 2348-8379
DOI: 10.14445/23488379/ijeee-v7i6p103