Automatic Detection of Pulmonary Embolism in CTA Images
نویسندگان
چکیده
منابع مشابه
Fully Automatic Segmentation and Detection of Pulmonary Artery and Embolism in CTA images
Computer Aided Detection (CAD) system for detection of pulmonary embolism (PE) is proposed in CT angiography images. Our approach consists of three stages: firstly the pulmonary artery (PA) tree is extracted from the thorax in order to reduce the search area aiming to reduce the number of false positives. In the second step, PE candidates are detected within the segmented PA by using several in...
متن کاملA dataset for Computer-Aided Detection of Pulmonary Embolism in CTA images
Todays, researchers in the field of Pulmonary Embolism (PE) analysis need to use a publicly available dataset to assess and compare their methods. Different systems have been designed for the detection of pulmonary embolism (PE), but none of them have used any public datasets. All papers have used their own private dataset. In order to fill this gap, we have collected 5160 slices of computed to...
متن کاملAn Automatic Detection of the Fire Smoke Through Multispectral Images
One of the consequences of a fire is smoke. Occasionally, monitoring and detection of this smoke can be a solution to prevent occurrence or spreading a fire. On the other hand, due to the destructive effects of the smoke spreading on human health, measures can be taken to improve the level of health services by zoning and monitoring its expansion process. In this paper, an automated method is p...
متن کاملAutomatic Ascending Aorta Detection in CTA Datasets
The assessment of coronary arteries is an essential step when diagnosing coronary heart diseases. There exists a wide range of specialized algorithms for the segmentation of the coronary arteries in Computed Tomography Angiography datasets. In general, these algorithms have to be initialized by manually placing a seed point at the origins of the coronary arteries or within the ascending aorta. ...
متن کاملAutomatic detection of liver tumor motion by fluoroscopy images
Background: A method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. Materials and Methods: The method was based on the following idea: (i) Before treatment, a series of fluoroscopic images corresponding to different bre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Medical Imaging
سال: 2009
ISSN: 0278-0062,1558-254X
DOI: 10.1109/tmi.2009.2013618