OBJECTIVE We propose a new method for automatic detection of fast ripples (FRs) which have been identified as a potential biomarker of epileptogenic processes. METHODS This method is based on a two-stage procedure: (i) global detection of events of interest (EOIs, defined as transient signals accompanied with an energy increase in the frequency band of interest 250-600Hz) and (ii) local energ...
متن کاملAutomatic detection of fast ripples 1
Highlights 1 1) We propose a novel method for automatically detecting fast ripples (FRs, 250-600 Hz) 2 2) The signal energy in low and high frequency bands is used to classify EEG events as FRs, interictal 3 epileptic spikes or artifacts. 4 3) The sensitivity and the specificity of this method is high enough to avoid " false ripples " caused by 5 sharp transients. 6 7 8 9 Abstract 10 Objective:...
متن کاملA Fast, Robust, Automatic Blink Detector
Introduction “Blink” is defined as closing and opening of the eyes in a small duration of time. In this study, we aimed to introduce a fast, robust, vision-based approach for blink detection. Materials and Methods This approach consists of two steps. In the first step, the subject’s face is localized every second and with the first blink, the system detects the eye’s location and creates an ope...
متن کاملNeurons Skip a Beat during Fast Ripples
Fast ripples are EEG transients emanating from epileptic foci, but fast-ripple frequencies far exceed maximal neuronal firing rates. In this issue of Neuron, Menendez de la Prida and coworkers propose that out-of-phase firing of a subpopulation of neurons during physiological ripple activity effectively doubles the ripple frequency to produce fast ripples.
متن کاملautomatic detection of the optic disc of the retina: a fast method
localizing the optic disc (od) in retinal fundus images is of critical importance, since it is very similar to hard exudates (found in pathology) in color and brightness. because of the importance of od localization in clinical applications, many techniques have been developed. in this paper, we present the results obtained from two methods, correlation and least square, to approximate the opti...