Automatic detection and inpainting of specular reflections for colposcopic images
نویسندگان
چکیده
منابع مشابه
Automatic Detection of Specular Reflections in Uterine Cervix Images
Specular reflections strongly affect the appearance of images, and usually hinder the computer vision algorithms applied to them. This is particularly the case with uterine cervix images. The highlights created by specular reflections are a major obstacle in the way of automatic segmentation of such images. We propose a method for the detection of specularities in cervix images that utilizes in...
متن کاملAdaptive specular reflection detection and inpainting in colonoscopy video frames
Colonoscopy video frames might be contaminated by bright spots with unsaturated values known as specular reflection. Detection and removal of such reflections could enhance the quality of colonoscopy images and facilitate diagnosis procedure. In this paper we propose a novel two-phase method for this purpose, consisting of detection and removal phases. In the detection phase, we employ both HSV...
متن کاملAn Automatic Detection of the Fire Smoke Through Multispectral Images
One of the consequences of a fire is smoke. Occasionally, monitoring and detection of this smoke can be a solution to prevent occurrence or spreading a fire. On the other hand, due to the destructive effects of the smoke spreading on human health, measures can be taken to improve the level of health services by zoning and monitoring its expansion process. In this paper, an automated method is p...
متن کاملClassification of weak specular reflections in laparoscopic images
Specular reflections are present in the majority of laparoscopic videos. If not considered they will affect all further image analysis and registration algorithms. In most state-of-the-art algorithms, segmentation of specular reflections is done by intensity thresholding. However, the strong reflections are detected but the weak reflections are missed. The proposed method automatically detects ...
متن کاملAutomatic detection of liver tumor motion by fluoroscopy images
Background: A method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. Materials and Methods: The method was based on the following idea: (i) Before treatment, a series of fluoroscopic images corresponding to different bre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Open Computer Science
سال: 2011
ISSN: 2299-1093
DOI: 10.2478/s13537-011-0020-2