Automated ocular artifact removal: comparing regression and component-based methods

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated ocular artifact removal: comparing regression and component-based methods

Objective: The aim is to compare various fully automated methods for reducing ocular artifacts from EEG recordings. Methods: Seven automated methods including regression, six component-based methods for reducing ocular artifacts have been applied to 36 data sets from two different labs. The influence of various noise sources is analyzed and the ratio between corrected and uncorrected EEG spectr...

متن کامل

Improving MEG source localizations: An automated method for complete artifact removal based on independent component analysis

The major limitation for the acquisition of high-quality magnetoencephalography (MEG) recordings is the presence of disturbances of physiological and technical origins: eye movements, cardiac signals, muscular contractions, and environmental noise are serious problems for MEG signal analysis. In the last years, multi-channel MEG systems have undergone rapid technological developments in terms o...

متن کامل

Ocular Artifact Removal from EEG Using Stationary Wavelet Enhanced ICA

To analyze EEG accurately, it is necessary to remove artifacts from EEG, which gets coupled with signal at the time of recording and can’t be eliminated at preprocessing stage. Ocular artifact is most obvious artifact in EEG. In this paper, a new method using Stationary Wavelet Enhanced Independent Component Analysis with a novel thresholding, is proposed for ocular artifact removal from EEG. P...

متن کامل

Iterative Subspace Decomposition for Ocular Artifact Removal from EEG Recordings

In this study, we present a method to remove ocular artifacts from electroencephalographic (EEG) recordings. This method is based on the detection of the EOG activation periods from a reference EOG channel, definition of covariance matrices containing the nonstationary information of the EOG, and applying generalized eigenvalue decomposition (GEVD) onto these matrices to rank the components in ...

متن کامل

Automatic correction of ocular artifacts in the EEG: a comparison of regression-based and component-based methods.

A variety of procedures have been proposed to correct ocular artifacts in the electroencephalogram (EEG), including methods based on regression, principal components analysis (PCA) and independent component analysis (ICA). The current study compared these three methods, and it evaluated a modified regression approach using Bayesian adaptive regression splines to filter the electrooculogram (EOG...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nature Precedings

سال: 2009

ISSN: 1756-0357

DOI: 10.1038/npre.2009.3446.1