Automated measurement of amylase isoenzymes with 4-nitrophenyl-maltoheptaoside as substrate and use of a selective amylase inhibitor.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated measurement of amylase isoenzymes with 4-nitrophenyl-maltoheptaoside as substrate and use of a selective amylase inhibitor.

We automated a kinetic procedure for determining amylase isoenzymes in serum and urine samples. We used 4-nitro-phenylmaltoheptaoside as substrate and a selective amylase inhibitor with the Abbott-VP bichromatic system. By use of the maximum differences between pancreatic (P) and salivary (S) amylase activities remaining after inhibition by the selective inhibitor and by use of the linear range...

متن کامل

Automated measurement of amylase isoenzymes by a double kinetic assay with "blocked" beta-2-chloro-4-nitrophenyl maltopentaoside as substrate and with wheat germ inhibitor.

We evaluated the enzymic mechanism by which 3-keto butylidene-beta-2-chloro-4-nitrophenyl maltopentaoside (3KB-G5-CNP) serves as a substrate for serum pancreatic (p-) and salivary (s-) amylases. In aliquots of the reaction mixture, three kinds of beta-2-chloro-4-nitrophenyl oligosaccharides (glucose, maltoside, and maltotrioside) were separated from the substrate by high-performance liquid chro...

متن کامل

Catalytic concentrations of amylase isoenzymes: an assay with wheat-germ inhibitor and 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate.

We coupled a kinetic procedure to a selective inhibiting method for determining amylase isoenzymes in biological samples, using 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate and a wheat-germ selective inhibitor with the Gilford S-III spectrophotometer. On plotting remaining amylase activities/total amylase activities (R/T) vs pancreatic amylase activities/salivary a...

متن کامل

Determinations of amylase isoenzymes in serum by use of a selective inhibitor.

A simple, rapid screening procedure for determining the relative amounts of pancreatic (P)- and salivary (S)-type amylase in serum is presented, involving incorporation of a selective inhibitor (from wheat-germ) into commercially available BMD Single-Vial Amylase and Beckman Enzymatic Amylase-DS procedures for manual and automated isoamylase measurements. Optimal concentrations of inhibitor inh...

متن کامل

Reference Ranges for ot-Amylase in Serum and Urine with 4?6-Ethylidene-(G7)-l-4-nitrophenyl-(Gl)-a5D-maltoheptaoside äs Substrate

Reference ranges for -amylase in serum, spontaneously voided urine, and 24h urine were determined, using 4,6-ethylidene-(G7)-l-4-nitrophenyl-(Gl)-a,£)-malthoheptaoside äs the Substrate (EPS method), at 25, 30, and 37 °C. The measured values were evaluated with and without the use of a factor which converts the results of the -amylase EPS method into values comparable to those obtained with the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Chemistry

سال: 1984

ISSN: 0009-9147,1530-8561

DOI: 10.1093/clinchem/30.7.1219