Automated Continuous-Flow Thermal-Diffusion-Chamber Type Ice Nucleus Counter
نویسندگان
چکیده
منابع مشابه
A Continuous - Flow Streamwise Thermal - Gradient CCN Chamber for Atmospheric 4 Measurements 5 Short Title : Continuous - Flow Streamwise CCN Chamber
24 We have addressed the need for improved measurements of cloud condensation nuclei 25 (CCN) by developing a continuous-flow instrument that provides in situ measurements of CCN. 26 The design presented in this paper can operate between 0.1% and 3% supersaturation, at 27 sampling rates sufficient for airborne operation. The design constitutes a cylindrical continuous28 flow thermal-gradient di...
متن کاملA Dual Diffusion Chamber for Observing Ice Crystal Growth on c-Axis Ice Needles
We describe a dual diffusion chamber for observing ice crystal growth from water vapor in air as a function of temperature and supersaturation. In the first diffusion chamber, thin c-axis ice needles with tip radii ∼ 100 nm are grown to lengths of ∼ 2 mm. The needle crystals are then transported to a second diffusion chamber where the temperature and supersaturation can be independently control...
متن کاملResults from the University of Toronto continuous flow diffusion chamber at ICIS 2007: instrument intercomparison and ice onsets for different aerosol types
The University of Toronto continuous flow diffusion chamber (UT-CFDC) was used to study heterogeneous ice nucleation at the International Workshop on Comparing Ice Nucleation Measuring Systems (ICIS 2007) which also represented the 4-th ice nucleation workshop, on 14–28 September 2007. One goal of the workshop was to intercompare different ice nucleation measurement techniques using the same ae...
متن کاملManchester Ice Nucleus Counter ( MINC ) measurements from the 2007 International workshop on Comparing Ice nucleation Measuring Systems ( ICIS - 2007 )
An ice nucleus counter was developed and constructed to enable investigation of potential ice nucleating materials. The Manchester Ice Nucleus Chamber (MINC) is a concentric-cylinder continuous flow diffusion chamber (CFDC). A full explanation of the MINC instrument is given here, along with first results and a comparison to an established instrument of similar design (Colorado State University...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: SOLA
سال: 2011
ISSN: 1349-6476
DOI: 10.2151/sola.2011-008