Audiometric findings in children with a large vestibular aqueduct.
OBJECTIVE To characterize audiometric findings in children with a large vestibular aqueduct (LVA). DESIGN Retrospective review. METHODS Audiometric records of children with an isolated LVA, diagnosed by computed tomography of the temporal bone, from 1995 through 1998 were reviewed. RESULTS Nineteen children had an isolated LVA in one or both ears. In all, 26 ears with an isolated LVA were...
متن کاملLarge vestibular aqueduct syndrome.
A large vestibular aqueduct is one of the commonest radiological abnormalities of the inner ear. A case of acute profound unilateral sensorineural hearing loss and balance disturbance following minor head trauma in the presence of an abnormally enlarged vestibular aqueduct is described. The significance of a diagnosis of large vestibular aqueduct syndrome, in the presence of serviceable hearing...
متن کاملCochlear implant and large vestibular aqueduct syndrome in children.
UNLABELLED Children with LVAS can develop a severe sensorineural hearing loss early in childhood, but they can be rehabilitated with hearing aids to continue their regular studies and to have a normal life. The problem is that they can deteriorate their hearing capacity, and at this point a cochlear implant can be used to preserve their hearing skills and vocalization. AIM to evaluate the hea...
متن کاملVestibular pathology in children with enlarged vestibular aqueduct.
OBJECTIVES/HYPOTHESIS To establish the prevalence of abnormal vestibular test findings in children with enlarged vestibular aqueduct (EVA) and determine if these findings correlate with clinical symptoms, radiographic findings (EVA size and laterality), audiometric findings, and genetic testing in these patients. STUDY DESIGN Prospective cohort. METHODS Patients 3 to 12 years of age with he...
متن کاملLarge vestibular aqueduct syndrome: a case study.
A 23-month-old female was referred for hearing aid fitting after failing newborn hearing screening and being diagnosed with significant hearing loss through subsequent diagnostic testing. Auditory brainstem response (ABR) and behavioral testing revealed a moderate-to-severe bilateral mixed hearing loss. Prior to the hearing aid evaluation, tympanostomy tubes had been placed bilaterally with lit...