Attachment systems for implant supported complete dentures
نویسندگان
چکیده
منابع مشابه
EffECT Of UsINg ATTAChmENT ON ImplANT sUppORTED DIsTAl ExTENsION lOwER pARTIAl OvER-DENTUREs
This study was performed to evaluate the effect of using attachment on implant supported distal extension lower partial overdenture. Ten lower kennedy class II partially edentulous patients were selected to receive implant at second molar area, then patients were divided into 2 groups according to the implant superstructures either (dome shaped-or-ball and cap attachment). Patients of both grou...
متن کاملComparison of patient's satisfaction with implant-supported mandibular overdentures and complete dentures.
BACKGROUND The purpose of this study was to compare patients' subjective experiences with respect to long-term satisfaction with mandibular implant-retained overdentures versus conventional complete dentures. METHODS Among 85 completely edentulous patients, 60 were treated with four one-stage titanium implants and overdentures retained by a cast bar with extracoronal attachments. These patien...
متن کاملTotal CAD/CAM Supported Method for Manufacturing Removable Complete Dentures
The incorporation of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture fabrication brings about several advantages to the fabrication process, providing better predictability of the desired outcomes and high accuracy of denture fit, mainly because the milling of prepolymerized acrylic resin eliminates the shrinkage of the acrylic base. Also, there is ...
متن کاملOcclusal force pattern in dentitions with mandibular implant-supported fixed cantilever prostheses occluded with complete dentures.
Naturally occurring axially directed closing and chewing forces were measured in ten patients with mandibular fixture-supported cross-arch prostheses occluding with maxillary complete dentures. The design of the mandibular constructions was characterized by bilateral posterior two-unit cantilevers. The forces were measured using eight miniature strain gauge transducers mounted in the maxillary ...
متن کاملRetrospective analysis of complications associated with implant supported partial dentures
Corresponding author:Tahseen Fatima Consultant Prosthodontist, Dr. Anwar Dental Hospital Ftaehgarh, Farrukhabad (U.P.)Email:[email protected] This article may be cited as:Fatima T Retrospective analysis of complications associated with implant supported partial dentures.Int J Com Health and Med Res 2016;2(4):38-41 Article Received: 19-09-16 Accepted On: 09-10-2016 NTRODUCTION Mechanical co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Ege University School of Dentistry
سال: 2010
ISSN: 1302-7476
DOI: 10.5505/eudfd.2010.24865