Atomic Motion Observed with the IBM Sub-Angstrom STEM
نویسندگان
چکیده
منابع مشابه
Interfacial atomic structure analysis at sub-angstrom resolution using aberration-corrected STEM
The atomic structure of a SiGe/Si epitaxial interface grown via molecular beam epitaxy on a single crystal silicon substrate was investigated using an aberration-corrected scanning transmittance electron microscope equipped with a high-angle annular dark-field detector and an energy-dispersive spectrometer. The accuracy required for compensation of the various residual aberration coefficients t...
متن کاملDirect Imaging of Water/Lipid Interface by Frequency Modulation Atomic Force Microscopy at Sub-Angstrom Resolution
Frequency modulation atomic force microscopy (FM-AFM) has been used in ultra high vacuum (UHV) environments for investigating subnanometer-scale structures and functions of various surfaces. Until recently, however, its operating environment had been limited only to UHV, which has prevented its practical applications in air and liquids. Recently, Fukuma et al. presented a way to overcome this l...
متن کاملPrecision Limits to STEM Imaging from Dynamical Scattering and Channeling of Sub-Angstrom Electron Probes
Precision smaller than the resolution is routinely achieved in electron microscopy, with 3-5 pm being the best reported for STEM [1], compared to 1-3 pm for TEM [2]. The signal to noise ratio (SNR) introduces the fundamental precision limit in STEM and TEM images. However, before the fundamental limit is reached, practical limits are usually encountered, such as image distortions caused by inst...
متن کاملModal interference in optical nanofibers for sub-Angstrom radius sensitivity
FREDRIK K. FATEMI,* JONATHAN E. HOFFMAN, PABLO SOLANO, ELIOT F. FENTON, GUY BEADIE, STEVEN L. ROLSTON, AND LUIS A. OROZCO Army Research Laboratory, Adelphi, Maryland 20783, USA Joint Quantum Institute, Department of Physics, University of Maryland and National Institute of Standards and Technology, College Park, Maryland 20742, USA Naval Research Laboratory, Washington, DC 20375, USA *Correspon...
متن کاملImaging columns of the light elements carbon, nitrogen and oxygen with sub Angstrom resolution.
It is reported that lattice imaging with a 300 kV field emission microscope in combination with numerical reconstruction procedures can be used to reach an interpretable resolution of about 80 pm for the first time. A retrieval of the electron exit wave from focal series allows for the resolution of single atomic columns of the light elements carbon, nitrogen, and oxygen at a projected nearest ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2005
ISSN: 1431-9276,1435-8115
DOI: 10.1017/s1431927605508596