Atomic absorption spectrometry of mercury using graphite furnace atomizer
نویسندگان
چکیده
منابع مشابه
GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MAlIlRIX MODIFICATION FOR DETERMINATION OF LEAD IN DRINKING WATER
An amoniumvanadate plus sodium molybdate mixed modifier Graphite Furnace Atomic Absorption Spectrometric method has been developed for determination of traces of lead in drinking water. The concentration of lead in the sample is obtained by direct comparison to linear working graph prepared from aqueous standards in the modifier medium, The results indicate the better performance of the pro...
متن کاملdirect determination of arsenic in potassium citrate tablet using graphite furnace atomic absorption spectrometry
in this study, a rapid and simple method based on graphite furnace atomic absorption spectrometry (gfaas) is described for direct determination of arsenic in potassium citrate tablet samples. pyrolytic graphite tubes were used as atomizers. nickel nitrate was used as chemical modifier. the ashing and atomization temperature and the concentration of modifier were also optimized. the detection li...
متن کاملComparative measurement of gas temperature in a graphite atomizer by a two-line method of iron and nickel spectral lines in graphite furnace atomic absorption spectrometry.
The gas temperature of atomospheric gas in a graphite atomizer was measured during an atomization stage in graphite furnace atomic absorption spectrometry (GF-AAS), by using a two-line method under the assumption of Boltzmann distribution. Iron and nickel were chosen as the probe elements to compare the gas temperatures obtained with different pairs of spectral lines. The atomic absorptions of ...
متن کاملgraphite furnace atomic absorption spectrometry with malilrix modification for determination of lead in drinking water
an amoniumvanadate plus sodium molybdate mixed modifier graphite furnace atomic absorption spectrometric method has been developed for determination of traces of lead in drinking water. the concentration of lead in the sample is obtained by direct comparison to linear working graph prepared from aqueous standards in the modifier medium, the results indicate the better performance of the propose...
متن کاملDirect Determination of Tin in Human Hair by Graphite Furnace Atomic Absorption Spectrometry Using Air Ashing in Graphite Tube
Direct determination of tin in human hair was performed by graphite furnace atomic absorption spectrometry. Human hair was cut into 3-5 mm long and 1-2 mg of the sample was directly introduced into a pyrolytically coated graphite tube, of which the injection hole was enlarged to a diameter of approximately 5 mm. After introduction of the sample, 20 μl of 30 mg Pd/l in 1 mol/l HCl was added as a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1977
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.26.11_772