For applications in faint -object spectroscopy at the Mt. Hopkins Observatory, a photon counting detector has been built using a dual 936 Reticon diode array fibre -optically coupled to a high -gain image intensifier package. The electronic signal processing follows closely the design of Shectman; the diode array is scanned every millisecond, each frame is subtracted from the previous to minimi...
متن کاملPerformance of single-photon-counting PILATUS detector modules
PILATUS is a silicon hybrid pixel detector system, operating in single-photon-counting mode, that has been developed at the Paul Scherrer Institut for the needs of macromolecular crystallography at the Swiss Light Source (SLS). A calibrated PILATUS module has been characterized with monochromatic synchrotron radiation. The influence of charge sharing on the count rate and the overall energy res...
متن کاملPhoton counting with a loop detector.
We propose a design for a photon-counting detector that is capable of resolving multiphoton events. The basic element of the setup is a fiber loop, which traps the input field with the help of a fast electro-optic switch. A single weakly coupled avalanche photodiode is used to detect small portions of the signal field extracted from the loop. We analyze the response of the loop detector to an a...
متن کاملImproved photon-counting detector performance by intelligent management of detector deadtime
We discuss the difficulties of photon-counting at extremely high rates and introduce a scheme for a photon-counting detection system that addresses these difficulties. The method uses an array of N detectors and a 1-by-N optical switch with a control circuit to direct input light to live detectors. We compare performance of our system to other, passive detection systems and show that our detect...
متن کاملSmall-angle scatter tomography with a photon-counting detector array.
Small-angle x-ray scatter imaging has a high intrinsic contrast in cancer research and other applications, and provides information on molecular composition and micro-structure of the tissue. In general, the implementations of small-angle coherent scatter imaging can be divided into two main categories: direct tomography and angular dispersive computerized tomography. Based on the recent develo...