Assessment of the posterior corneal surface changes after LASIK treatment of myopia using Pentacam
نویسندگان
چکیده
منابع مشابه
Posterior Corneal Curvature Assessment after Epi-LASIK for Myopia: Comparison of Orbscan II and Pentacam Imaging
PURPOSE To compare the changes in posterior corneal curvature using scanning slit topography (Orbscan II) and Scheimpflug imaging (Pentacam) before and after Epi-laser in situ keratomileusis (LASIK) for myopia. METHODS In a prospective observational case-series study, 20 myopic patients having undergone Epi-LASIK were examined serially with two different devices, Orbscan II and Pentacam, preo...
متن کاملEvaluation of corneal changes after myopic LASIK using the Pentacam®
BACKGROUND In this study, we used a Pentacam® device to evaluate the corneal changes that occur after laser-assisted in situ keratomileusis (LASIK). METHODS Our study included 60 eyes of 32 patients. All patients were treated for myopia and myopic astigmatism using LASIK. The eyes were examined preoperatively and 3 months postoperatively using a Pentacam to assess corneal changes with regard ...
متن کاملassessment of the efficiency of s.p.g.c refineries using network dea
data envelopment analysis (dea) is a powerful tool for measuring relative efficiency of organizational units referred to as decision making units (dmus). in most cases dmus have network structures with internal linking activities. traditional dea models, however, consider dmus as black boxes with no regard to their linking activities and therefore do not provide decision makers with the reasons...
The Changes of Posterior Corneal Surface and High-Order Aberrations after Refractive Surgery in Moderate Myopia
PURPOSE To compare forward shift of posterior corneal surface and higher-order aberration (HOA) changes after LASIK, LASEK, and wavefront-guided LASEK surgery in moderate myopia METHODS One hundred eighty four eyes undergoing LASIK, LASEK and wavefront-guided LASEK with VISX STAR S4 were included in this study. The posterior corneal elevation was measured with Orbscan before, 2 and 4 months a...
متن کاملComparison of central corneal thickness measurements using Pentacam and ultrasonic pachymetry in post-LASIK eyes for myopia.
PURPOSE To compare central corneal thickness (CCT) measurements obtained using the Pentacam Scheimpflug system with those obtained using DGH ultrasound pachymetry (UP) in post-laser in situ keratomileusis (LASIK) eyes for myopia. METHODS In a prospective study, measurement agreement was assessed in 143 eyes of 72 post-LASIK patients using both the Pentacam and UP at the Eye Consultants Center...