Assessment of Seismic Capacity for Reinforced Concrete Frames with Perforated Unreinforced Brick Masonry Infill Wall

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Unreinforced Masonry Infill Walls on Seismic Performance of Reinforced Concrete Framed Structures

Unreinforced Masonry infill walls (URM) are commonly used in the Reinforced Concrete (RC) framed structures as interiors and exteriors partition walls. Although they usually are not considered in the structural analysis and design, their influence on the seismic performance of the framed structures is significant. A common practice in the modern and old RC buildings is to remove the URM walls i...

متن کامل

Study the Reinforced Concrete Frame with Brick Masonry Infill due to Lateral Loads

In the building construction, framed structures are frequently used due to ease of construction and rapid progress of work. Masonry infill panels have been widely used as interior and exterior partition walls for aesthetic reasons and functional needs. When infill walls are omitted in a particular storey, a soft storey is formed compared to much stiffer other stories. The masonry infill has bee...

متن کامل

Assessment of Masonry Infilled Reinforced-concrete Frames with Openings

Original scientific paper Reinforced-concrete (R/C) frames infilled with masonry wall, especially with the presence of an opening, are insufficiently explored structural elements. We have experimentally investigated influence of the opening’s type and position to the lateral response of reinforced-concrete frames with masonry infill. Correction factors, that take into account influence of the o...

متن کامل

بررسی آزمایشگاهی عملکرد میان قاب های مصالح بنایی در قاب های بتنی

An experimental study is conducted on three ½ scales, single-story, single-bay, frame specimens. The first specimen was a reinforced concrete frame with solid-brick infill. The second specimen was a reinforced concrete frame with hollow clay perforated-brick infill. The last specimen was a reinforced concrete frame without any infill. These three specimens were tested by pseudostatic method. Di...

متن کامل

Effective stiffness of unreinforced brick masonry walls

Code design of Unreinforced Masonry (URM) buildings is based on elastic analysis, which requires as input parameter the effective stiffness of URM walls. Current approaches estimate the effective stiffness as fixed ratio of the gross sectional stiffness but comparisons with experimental results have shown that this does not yield satisfactory predictions. In this paper, a recently developed ana...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Civil Engineering Journal

سال: 2020

ISSN: 2476-3055,2676-6957

DOI: 10.28991/cej-2020-03091625