Assessment of implant stability by resonant frequency analysis.

The hardness of compact bone is about 10 times higher than cancellous (trabecular) bone, thanks to both its density and mineralization. The higher bone density gives the higher primary implants stability values . Considering that cancellous bone has lower biomechanical values, some authors like to name it ‘lower quality bone’, which is not quite exact and correct term. It is better to name it –...

متن کامل

Resonance frequency analysis of implant stability in augmented and non-augmented sinus sites

Background and aim:  Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...

متن کامل

RESONANCE FREQUENCY ANALYSIS FOR IMPLANT STABILITY MEASUREMENTS. A review

The resonance frequency analysis (RFA) technique for implant stability measurements was developed by Meredith and coworkers more than 20 years ago. RFA makes use of a transducer (peg), which is attached to the implant and excited over a range of frequencies by electro-magnetic waves to measure the resonance frequency (RF) of the transducer. The underlying RF measurements in Hz are translated to...

متن کامل

Measurement of dental implant stability by resonance frequency analysis: a review of the literature.

Dental implant treatment is an excellent option for prosthetic restoration that is associated with high success rates. Implant stability is essential for a good outcome. The clinical assessment of osseointegration is based on mechanical stability rather than histological criteria, considering primary stability (absence of mobility in bone bed after implant insertion) and secondary stability (bo...

متن کامل

Implant stability comparison of immediate and delayed maxillary implant placement by use of resonance frequency analysis--a clinical study.

The purpose of this study was to objectively evaluate the stability of dental implants by use of resonance frequency analysis (RFA). In this study, 60 Nobel Replace Tapered Groovy implants were placed in the premolar region of the maxilla in 60 patients. Thirty implants were placed immediately after tooth extraction and 30 implants were placed in healed bone sites. Implant stability quotient (I...