Assessment of an endotracheal tube cleaning closed-suctioning system by micro-computed tomography: preliminary clinical data

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of a novel cleaning closed suction system reduces the volume of secretions within the endotracheal tube as assessed by micro-computed tomography: a randomized clinical trial.

BACKGROUND Early after intubation, a layer of biofilm covers the inner lumen of the endotracheal tube (ETT). Cleaning the ETT might prevent airways colonization by pathogens, reduce resistance to airflow, and decrease sudden ETT obstruction. We investigated the effectiveness of a cleaning closed suction system in maintaining the endotracheal tube free from secretions. METHODS We conducted a s...

متن کامل

Measurement of endotracheal tube secretions volume by micro computed tomography (MicroCT) scan: an experimental and clinical study

BACKGROUND Biofilm accumulates within the endotracheal tube (ETT) early after intubation. Contaminated secretions in the ETT are associated with increased risk for microbial dissemination in the distal airways and increased resistance to airflow. We evaluated the effectiveness of micro computed tomography (MicroCT) for the quantification of ETT inner volume reduction in critically ill patients....

متن کامل

Case study involving suctioning of an electromyographic endotracheal tube.

The electromyographic endotracheal tube (EMG-ETT) is a relatively new tool used to measure integrity of the vocal cord structures during surgery. We describe a case in which an EMG-ETT was inserted for the operative period but not replaced with an ETT during the immediate postoperative period. Intensive care unit nurses had difficulty suctioning the EMG-ETT. The patient was not provided the pul...

متن کامل

the effect of open and closed endotracheal tube suctioning system on respiratory parameters of infants undergoing mechanical ventilation

background : mechanical ventilation is used for some infants in neonatal intensive care units (nicu) due to many physiological and clinical causes. since these patients have endotracheal tubes, cleaning and keeping the airways open through suctioning should be done to increase oxygenation. this study aimed to evaluate effect of open and closed suctioning methods on respiratory parameters of inf...

متن کامل

Open versus Closed Endotracheal Suctioning in the Intensive Care Comparison of Closed Endotracheal Suction Versus

BACKGROUND: Ventilator-associated pneumonia (VAP), a frequent nosocomial infection in the intensive care, is associated with considerable morbidity. Endotracheal suctioning is routinely performed in mechanically ventilated patients to clear secretions. This study assessed if there were advantages of closed endotracheal suctioning (CES) over open endotracheal suctioning (OES) with respect to cli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Critical Care

سال: 2014

ISSN: 1364-8535

DOI: 10.1186/cc13508