DC circuit breakers are required to interrupt dc faults in multi-terminal HVDC (MTDC) grids. Consequently, their current limiting inductors can substantially impact the dynamic performance and stability of MTDC However, literature does not address assessment mitigation breaker inductance impacts on an grid equipped with a power flow controller (PFC). To fill this gap, paper evaluates effects PFC-equipped grid. Furthermore, expands capability PFC via development PFC-based damping improve enhance its damping. First, comprehensive small-signal model is developed. Then, eigenvalue frequency response analyses employed assess grid, considering inductances, converter station control parameters, network parameter uncertainty. Finally, time-domain simulations hardware-in-the-loop real-time carried out evaluate proposed verify theoretical analysis.
منابع مشابه
Study of Power Flow Algorithm of AC/DC Distribution System including VSC-MTDC
In recent years, distributed generation and a large number of sensitive AC and DC loads have been connected to distribution networks, which introduce a series of challenges to distribution network operators (DNOs). In addition, the advantages of DC distribution networks, such as the energy conservation and emission reduction, mean that the voltage source converter based multi-terminal direct cu...
متن کاملSimultaneous Stabilization of Power Systems Equipped with Unified Power Flow Controller Using Particle Swarm
In this paper, the use of the supplementary controller of a unified power flow controller (UPFC) to damp low frequency oscillations in a weakly connected system is investigated. The potential of the UPFC supplementary controllers to enhance the dynamic stability is evaluated by measuring the electromechanical (EM) controllability through singular value decomposition (SVD) analysis. Individual d...
متن کاملEnhancement of Power Quality in Grid Integrated System using DC-link Voltage PI Controlled VSC based Statcom
This paper demonstrates an enhancement of power quality in grid integrated systems with the help of the proposed control strategy for voltage source converter based active power filters. The Shunt Active Power filters (SAPF) are extensively utilized in modern grid integrated systems to diminish the power quality concerns associated with it. The SAPF is one of the various power filters, which ha...
متن کاملInvestigating Impacts of Sustainable Repair Time and Circuit Breaker Model on Meshed Distribution Networks Reliability Assessment
Generally, the failure rate and the repair time of system components are constant parameters in reliability assessment of electric distribution systems. A failure of component is resulted from failing in the operation or overloading. In addition, there exist cases where, the repair times of components are small and tolerable from customer point of view. Thus, tolerable repair times may be overl...
متن کامل[email protected] A THREE LEVEL CASCADED VSC CONTROLLER AND TESTING ON CIGRE B4.58 DC GRID TEST SYSTEM
This paper proposes a three levels cascade control topology for the VSC and DC/DC converters used in DC grids. The inner control level regulates local current as in all VSC converters. The middle control level uses PI feedback control of local DC voltage on all terminals. At the highest level, each station reference DC voltage is set based on desired power transfer and observing DC voltage limi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE open journal of power electronics
سال: 2023
ISSN: ['2644-1314']