Assessing the results of anophthalmic prostheses
نویسندگان
چکیده
منابع مشابه
Assessing the utility of visual acuity measures in visual prostheses
There are presently several ongoing clinical trials to provide usable sight to profoundly visually impaired patients by means of electrical stimulation of the retina. Some of the blind patients implanted with retinal prosthesis reported un-patterned perception and yet benefit from the device in many activities of daily living, seemingly because they adopt active scanning strategies. The aim of ...
متن کاملThe challenge of assessing heart valve prostheses by Doppler echocardiography.
The assessment of prosthetic valve function remains challenging. Echocardiography has become the key diagnostic tool not only because of its noninvasive nature and wide availability but also because of limitations inherent in alternative diagnostic techniques. Invasive evaluation is limited particularly in mechanical valves that cannot be crossed with a catheter, and in patients with both aorti...
متن کاملThe Anophthalmic Socket – Reconstruction Options
Keeping the eye is impossible, functionality is lost and aesthetic requirements are high. What do we do? Which approach is right? This is the dilemma we face whenenucleation or evisceration are unavoidable. The patient loses a sensory organ with a very important function and, at the same time, is faced with a major aesthetic defect, leading to significant anxiety. The purpose of this article is...
متن کاملOssiculoplasty using hydroxyapatite prostheses: long-term results.
The surgical results of ossicular chain reconstruction using a hydroxyapatite prosthesis were evaluated in 106 ears of 101 patients who were followed up for > 5 years. Successful reconstruction was defined as: (1) postoperative air-bone gap of </= 20 db; or (2) postoperative air conduction better than 40 db; or (3) hearing gain better than 15 db. Success in hearing was obtained in 63/106 ears (...
متن کامل[Anophthalmic cavity and implant extrusion].
PURPOSE To evaluate the characteristics of patients with anophthalmic cavity who developed sphere extrusion. METHODS A retrospective observational study was done evaluating 37 patients with anophthalmic cavity and sphere extrusion at the "Faculdade de Medicina de Botucatu-UNESP". RESULTS Extrusion was observed in enucleated and eviscerated cavities. The majority of the patients had the eye ...