Ascending Aortic Length and Its Association With Type A Aortic Dissection
نویسندگان
چکیده
منابع مشابه
A Rare Case of Severe Aortic Regurgitation with Silent Ascending Aortic Dissection
Classically, ascending aortic dissection (AD) presents as sudden, severe chest pain that is tearing type and radiates to the back. Herein, we present a rare case of severe aortic regurgitation with silent ascending AD, which had no chest pain symptoms. The aortic valve apparatus probably masked this AD; therefore, it was not detected by echocardiography and during the surgery.
متن کاملAscending aortic cannulation for Stanford type A acute aortic dissection
Results Patient characteristics such as preoperative complications and shock status were almost similar between the groups. Although intraoperative parameters such as total cardiopulmonary bypass time, hypothermic circulatory arrest time, minimum bladder temperature and percentage of total arch replacement were also similar between the groups, ascending aortic cannulation significantly reduced ...
متن کاملsurgery of ascending aortic dissection , a six years experience
acute dissection or the ascending aorta requires immediate surgical intervention. without surgical treatment ii:i,) of the patients will die every hour. in this study we report the result ofoperations on patients with stanford type a aortic dissection. from 1997 to 2003. 26 patients (16 males, 10 females) aged 30 to 71 years (mean age 4~.9 :i: 2.3 years) underwent surgical treatment. in all of ...
متن کاملAscending aorta cannulation in acute type A aortic dissection.
OBJECTIVE Antegrade perfusion for type A acute aortic dissection prevents malperfusion and retrograde cerebral embolism during cardiopulmonary bypass. Prompt establishment of antegrade perfusion via ascending aorta may improve the surgical results of type A dissections, especially in the situations of hemodynamic instability. Thus, we evaluated the efficacy of use of the dissected ascending aor...
متن کاملType II A aortic dissection and ascending aort aneurysm seeing after mechanic aortic valve replacement
Results He had Type II A aortic dissection with intimal tear at proximal region of the right coronary ostium. Mechanic aortic valve was normal function. Ascending aorta was replaced by using 26 mm Dacron tube graft between annulus of previous mechanic aortic valve and distal ascending aort by using hypothermic circulatory arrest and antegrade selective cerebral perfusion. An 8 mm dacron tube gr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the American Heart Association
سال: 2021
ISSN: 2047-9980
DOI: 10.1161/jaha.120.020140