Artificial Sensitive Skin for Robotics Based on Electrical Impedance Tomography

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Applications of Electrical Impedance Tomography in Neurology

Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...

متن کامل

A novel post-processing scheme for two-dimensional electrical impedance tomography based on artificial neural networks

OBJECTIVE Electrical Impedance Tomography (EIT) is a powerful non-invasive technique for imaging applications. The goal is to estimate the electrical properties of living tissues by measuring the potential at the boundary of the domain. Being safe with respect to patient health, non-invasive, and having no known hazards, EIT is an attractive and promising technology. However, it suffers from a ...

متن کامل

A Deformable Smart Skin for Continuous Sensing Based on Electrical Impedance Tomography

In this paper, we present a low-cost, adaptable, and flexible pressure sensor that can be applied as a smart skin over both stiff and deformable media. The sensor can be easily adapted for use in applications related to the fields of robotics, rehabilitation, or costumer electronic devices. In order to remove most of the stiff components that block the flexibility of the sensor, we based the se...

متن کامل

Monotonicity-based Electrical Impedance Tomography Lung Imaging

This paper presents a monotonicity-based spatiotemporal conductivity imaging method for continuous regional lung monitoring using electrical impedance tomography(EIT). The EIT data (i.e., the boundary current-voltage data) can be decomposed into pulmonary, cardiac and other parts using their different periodic natures. The time-differential current-voltage operator corresponding to lung ventila...

متن کامل

Design of Voltage Measuring Circuits in Electrical Impedance Tomography Based on Dual Frequency Phase-Sensitive Demodulator

In this paper, a dual frequency phase sensitive demodulation (PSD) technique is suggested to measure electrode voltages in electrical impedance tomography. The simulation results obtained by the dual frequency PSD are compared with the single frequency PSD in terms of accuracy on a simple phantom.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Advanced Intelligent Systems

سال: 2020

ISSN: 2640-4567,2640-4567

DOI: 10.1002/aisy.202000151