Artifact-free deconvolution in light field microscopy
نویسندگان
چکیده
منابع مشابه
Light Field Blind Deconvolution
We address for the first time the issue of motion blur in light field images captured from plenoptic cameras (instead of camera arrays), where the spatial sampling in each view is decimated. We propose a solution to the estimation of a sharp light field given a blurry one, when the motion blur point spread function is unknown, i.e., the so-called blind deconvolution problem. Unfortunately, the ...
متن کاملCoherent artifact suppression in line-field reflection confocal microscopy using a low spatial coherence light source.
Line-field reflection confocal microscopy (LF-RCM) has the potential to add a dimension of parallelization to traditional confocal microscopy while reducing the need for two-axis beam scanning. LF-RCM systems often employ light sources with a high degree of spatial coherence. This high degree of spatial coherence potentially leads to unwanted coherent artifact in the setting of nontrivial sampl...
متن کاملDirect Imaging of Phase Objects Enables Conventional Deconvolution in Bright Field Light Microscopy
In transmitted optical microscopy, absorption structure and phase structure of the specimen determine the three-dimensional intensity distribution of the image. The elementary impulse responses of the bright field microscope therefore consist of separate absorptive and phase components, precluding general application of linear, conventional deconvolution processing methods to improve image cont...
متن کاملA workingperson's guide to deconvolution in light microscopy.
Thefluorescence microscope is routinely used to study cellular structure in many biomedical research laboratories and is increasingly used as a quantitative assay system for cellular dynamics. One of the major causes of image degradation in the fluorescence microscope is blurring. Deconvolution algorithms use a model of the microscope imaging process to either subtract or reassign out-of-focus ...
متن کاملNew techniques for motion-artifact-free in vivo cardiac microscopy
Intravital imaging microscopy (i.e., imaging in live animals at microscopic resolution) has become an indispensable tool for studying the cellular micro-dynamics in cancer, immunology and neurobiology. High spatial and temporal resolution, combined with large penetration depth and multi-reporter visualization capability make fluorescence intravital microscopy compelling for heart imaging. Howev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2019
ISSN: 1094-4087
DOI: 10.1364/oe.27.031644