Arthroscopic Cortical Button Stabilization of Isolated Acute Neer Type II Fractures of the Distal Clavicle.
Neer type II distal clavicle fractures are inherently unstable. The purpose of this study was to review the outcome of Neer type II distal clavicle fractures arthroscopically treated using a suspensory cortical button technique. Between 2008 and 2012, a total of 17 Neer type IIB fractures were managed operatively at the authors' institution. Functional outcomes were assessed using the pain scor...
متن کاملManagement of distal clavicle fractures.
Most clavicle fractures heal without difficulty. However, radiographic nonunion after distal clavicle fracture has been reported in 10% to 44% of patients. Type II distal clavicle fractures, which involve displacement, are associated with the highest incidence of nonunion. Several studies have questioned the clinical relevance of distal clavicle nonunion, however. Nonsurgical and surgical manag...
متن کاملManagement of distal clavicle fractures.
Management of type II distal clavicle fractures has always been a challenge. Non-operative treatment has a high risk of complications and should be considered only for elderly and frail patients. For younger and active patients there is a wide variety of operative options, each with advantages and disadvantages. According to our unit's experience the first choice could be hook plate fixation, w...
متن کاملArthroscopic Treatment of Distal Radius Fractures
Distal radius fracture (DRF) is one of the most common traumatic events for the hand surgeon to treat. Numerous surgical procedures have been described for this fracture (Ruch et al., 2004); however, the ideal method of surgical management is still controversial. The latest development of a volar locking plate fixation markedly changed the treatment of DRF (Chen & Jupiter, 2007; Chung et al., 2...
متن کاملFixation of unstable type II clavicle fractures with distal clavicle plate and suture button.
This article reports on a technique to treat unstable type II distal clavicle fractures using fracture-specific plates and coracoclavicular augmentation with a suture button. Six patients with clinically unstable type II distal clavicle fractures underwent treatment using the above technique. All fractures demonstrated radiographic union at 9.6 (8.4-11.6) weeks with a mean follow-up of 15.6 (12...