Arterial oxygen saturation profiles in healthy preterm infants
نویسندگان
چکیده
منابع مشابه
Arterial oxygen saturation profiles in healthy preterm infants.
AIM To construct a reference range of SpO2 values in healthy preterm infants using a simple data logging device. METHODS Thirty three healthy preterm infants were monitored for a continuous period of 4 hours at rest using an Ohmeda Biox 3700 E Pulse Oximeter and an electronic data logger (Rustrack Ranger). Stored data were downloaded and saved as individual files on a personal computer. RES...
متن کاملNocturnal oxygen saturation profiles of healthy term infants
OBJECTIVE Pulse oximetry is used extensively in hospital and home settings to measure arterial oxygen saturation (SpO2). Interpretation of the trend and range of SpO2 values observed in infants is currently limited by a lack of reference ranges using current devices, and may be augmented by development of cumulative frequency (CF) reference-curves. This study aims to provide reference oxygen sa...
متن کاملOxygen saturation and outcomes in preterm infants.
BACKGROUND The clinically appropriate range for oxygen saturation in preterm infants is unknown. Previous studies have shown that infants had reduced rates of retinopathy of prematurity when lower targets of oxygen saturation were used. METHODS In three international randomized, controlled trials, we evaluated the effects of targeting an oxygen saturation of 85 to 89%, as compared with a rang...
متن کاملEffect of Different Positions on Arterial Oxygen Saturation during Enteral Feeding of Preterm Infants Admitted to Neonatal Intensive Care Units
Background: This study aimed to determine the effects of various positions on the arterial oxygen saturation during enteral feeding of preterm infants admitted to Neonatal Intensive Care Units (NICUs). It is assumed that different body positions influence arterial oxygen saturation during enteral feeding.Methods: This crossover clinical trial included 88 infants. The inclusion criteria we...
متن کاملDiscrepancies between arterial oxygen saturation and functional oxygen saturation measured with pulse oximetry in very preterm infants.
BACKGROUND Discrepancies between pulse oximetry saturation (SpO(2)) and arterial saturation (SaO(2)) at low blood oxygenation values have been previously reported with significant variations among instruments and studies. Whether pulse oximeters that attenuate motion artifact are less prone to such discrepancies is not well known. OBJECTIVE To prospectively assess the agreement of the Masimo ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Archives of Disease in Childhood - Fetal and Neonatal Edition
سال: 1998
ISSN: 1359-2998,1468-2052
DOI: 10.1136/fn.79.1.f64