Array signal recovery algorithm for a single-RF-channel DBF array
نویسندگان
چکیده
منابع مشابه
Array signal recovery algorithm for a single-RF-channel DBF array
An array signal recovery algorithm based on sparse signal reconstruction theory is proposed for a single-RF-channel digital beamforming (DBF) array. A single-RF-channel antenna array is a low-cost antenna array in which signals are obtained from all antenna elements by only one microwave digital receiver. The spatially parallel array signals are converted into time-sequence signals, which are t...
متن کاملSingle-Channel Array Normalization (SCAN)
Briefly, SCAN is a single-sample approach for gene-expression microarrays. This means that the output for a given microarray sample will be the same whether that sample is processed in isolation or jointly with other samples. The probe-sequence content within each microarray is used to correct for binding-affinity biases that can arise during processing and to standardize variances across the p...
متن کامل32 Channel Coil Array for Parallel RF Transmission
Introduction: As part of a study that investigates a substantially distributed multi-channel parallel transmit approach, head-size 32-element transmit/receive arrays were developed. The specific goal of the coil development is to facilitate reduction of RF power dissipation in the imaged object / the coil structure, and to facilitate B1 shimming / accelerated parallel excitation for an arbitrar...
متن کاملRF transparent array for testing multi-channel transmit systems
Figure 3: Complete 8-channel transmit array in acrylic former Figure 4: Gradient echo images (TR=250 ms) of the individual coil elements shown in successive order, starting with the bottom element and working counter clockwise. There is no evidence of coupling with the body coil. The images were acquired using commercial power amplifiers and the conversion modules. RF transparent array for test...
متن کاملA 32 Channel RF array and integrated gradient insert
INTRODUCTION Neonatal MR is a particularly challenging application requiring fast imaging to reduce motion artifacts especially when anaesthetics are not used. However, on conventional MR system fast imaging sequences produce high levels of acoustic noise and can yield high SAR. Increased SNR and gradient strength can be achieved while obeying acoustic noise and SAR restrictions using smaller s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: EURASIP Journal on Advances in Signal Processing
سال: 2016
ISSN: 1687-6180
DOI: 10.1186/s13634-016-0391-6