Are Topical Steroids a Risk Factor for Tube Exposure in Glaucoma Drainage Devices?

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk factors for exposure of glaucoma drainage devices: a retrospective observational study

OBJECTIVES The purpose of this study was to identify risk factors for exposure of glaucoma drainage devices (GDD). SETTING This retrospective, observational study was conducted in the eye clinic of an academic medical centre. PARTICIPANTS Participants included 1073 consecutive adults who underwent GDD surgery between 1 January 2005 and 1 January 2011. Participants were included if chart rev...

متن کامل

Glaucoma drainage devices; past, present, and future.

Glaucoma filtration surgery (GFS) has been shown to be more eVective at preventing disease progression than other primary treatment modalities in open angle glaucoma. 2 If it were possible to avoid complications associated with poor flow control, primary GFS would probably be offered more widely. Trabeculectomy, the procedure of choice in conventional GFS, has remained essentially unchanged for...

متن کامل

Comparison of different biomaterials for glaucoma drainage devices.

OBJECTIVES To compare the inflammatory reaction associated with the insertion of silicone and polypropylene endplates and endplates made of a new biocompatible polymer, Vivathane, in the rabbit subconjunctival space. METHODS Similar-sized endplates made of 3 different biomaterials were sutured to the sclera in the superotemporal quadrant of the rabbit eye. Thirty eyes of 15 albino New Zealand...

متن کامل

Artificial drainage devices for glaucoma surgery: an overview.

Artificial drainage devices (ADD) create an alternative pathway for aqueous drainage from the anterior chamber of an eye through a tube to the subconjunctival bleb connected to an equatorial plate under the conjunctiva. The ADDs, both valved and non-valved, are available for end stage or refractory glaucoma. Currently, some of these devices, particularly the Express shunt, are recommended for t...

متن کامل

Comparison of different biomaterials for glaucoma drainage devices: part 2.

BACKGROUND Inflammation associated with biomaterials may contribute to the failure of glaucoma drainage devices. OBJECTIVE To compare the inflammatory reaction associated with the insertion of Krupin silicone, Molteno polypropylene, and Acrosof end plates in the subconjunctival space of rabbits. METHODS Similar-sized glaucoma end plates made of 3 different biomaterials were sutured to the s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Ophthalmology

سال: 2021

ISSN: 1177-5483

DOI: 10.2147/opth.s281384