Aptamer-Based Sensors for Thrombin Detection Application
نویسندگان
چکیده
Thrombin facilitates the aggregation of platelet in hemostatic processes and participates regulation cell signaling. Therefore, development thrombin sensors is conducive to comprehending role course a disease. Biosensors based on aptamers screened by SELEX have exhibited superiority for detection. In this review, we summarized aptamer-based detection which rely specific recognitions between aptamer. Meanwhile, unique advantages different including optical electrochemical were also highlighted. Especially, these electrochemistry potential be miniaturized, thus gained comprehensive attention. Furthermore, concerns about detection, prospects future promising avenues field presented.
منابع مشابه
Aptamer-based SERRS sensor for thrombin detection.
We describe an aptamer-based surface enhanced resonance Raman scattering (SERRS) sensor with high sensitivity, specificity, and stability for the detection of a coagulation protein, human alpha-thrombin. The sensor achieves high sensitivity and a limit of detection of 100 pM by monitoring the SERRS signal change upon the single-step of thrombin binding to immobilized thrombin binding aptamer. T...
متن کاملAptamer Based Microsphere Biosensor for Thrombin Detection
We have developed an optical microsphere resonator biosensor using aptamer as receptor for the measurement of the important biomolecule thrombin. The sphere surface is modified with anti-thrombin aptamer, which has excellent binding affinity and selectivity for thrombin. Binding of the thrombin at the sphere surface is monitored by the spectral position of the microsphere’s whispering gallery m...
متن کاملAnalytical performances of aptamer-based sensing for thrombin detection.
Aptamer-based assays represent a modern and attractive approach in bioanalytical chemistry. The DNA thrombin aptamer has been extensively investigated, and the coupling of this aptamer to different transduction principles has demonstrated the wide applicability of aptamers as bioreceptors in bioanalytical assays. The goal of this work was to critically evaluate all the parameters that can influ...
متن کاملTime-resolved fluorescence aptamer-based sandwich assay for thrombin detection.
In the present study, the authors report a novel sensitive method for the detection of thrombin using time-resolved fluorescence sensing platform based on two different thrombin aptamers. The thrombin 15-mer aptamer as a capture probe was covalently attached to the surface of glass slide, and the thrombin 29-mer aptamer was fluorescently labeled as a detection probe. A bifunctional europium com...
متن کاملAptamer functionalized microcantilever sensors for cocaine detection.
A cocaine-specific aptamer was used as a receptor molecule in a microcantilever-based surface stress sensor for detection of cocaine molecules. An interferometric technique that relies on measuring differential displacement between two microcantilevers (a sensing/reference pair) was utilized to measure the cocaine/aptamer binding induced surface stress changes. Sensing experiments were performe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Chemosensors
سال: 2022
ISSN: ['2227-9040']
DOI: https://doi.org/10.3390/chemosensors10070255