Applications and benefits of using gradient percentage depth dose instead of percentage depth dose for electron and photon beams in radiotherapy
نویسندگان
چکیده
منابع مشابه
Choice of a Suitable Dosimeter for Photon Percentage Depth Dose Measurements in Flattening Filter-Free Beams
The International Atomic Energy Agency Technical Reports Series-398 code of practice for dosimetry recommends measuring photon percentage depth dose (PDD) curves with parallel-plate chambers. This code of practice was published before flattening filter-free (FFF) beams were widely used in clinical linear accelerators. The choice of detector for PDD measurements needs to be reassessed for FFF be...
متن کاملPhoton Energy Spectrum Reconstruction Based on Monte Carlo and Measured Percentage Depth Dose in Accurate Radiotherapy
In accurate radiotherapy, energy spectra of high energy x-ray greatly affect the accuracy of dose calculation. Conventional discrete method failed to realize the stable solution, and the Schiff formula could not reflect the practical geometric shape of different linac system that showed the limitation to apply to other linacs. To obtain the photon energy spectra of linac in radiotherapy effecti...
متن کاملDetermination of Percentage Depth Dose (Pdd) of Pagat Gel Dosimeter By Electron Beams
Background: The purpose of this study was to determine the percentage depth dose (PDD) of PAGAT normoxic polymer gel dosimeter by electron beams using MRI technique for a standard clinically used Co-60 therapy unit and an electa linear accelerator. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,...
متن کاملPercentage depth dose evaluation in heterogeneous media using thermoluminescent dosimetry
The purpose of this study is to investigate the influence of lung heterogeneity inside a soft tissue phantom on percentage depth dose (PDD). PDD curves were obtained experimentally using LiF:Mg,Ti (TLD-100) thermoluminescent detectors and applying Eclipse treatment planning system algorithms Batho, modified Batho (M-Batho or BMod), equivalent TAR (E-TAR or EQTAR), and anisotropic analytical alg...
متن کاملEffect of Gold Nanoparticle on Percentage Depth Dose Enhancement On Megavoltage Energy in MAGICA Polymer Gel Dosimeter
Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date.Objective: The aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material.Methods: In this work t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Polish Journal of Medical Physics and Engineering
سال: 2021
ISSN: 1898-0309
DOI: 10.2478/pjmpe-2021-0004