Application of Routine Analysis Procedures to a Direct Mass Spectrometry Technique: Selected Ion Flow Tube Mass Spectrometry (SIFT-MS)

نویسندگان

چکیده

In recent years the environmental and human health impacts of volatile organic compounds (VOCs) have become more apparent, resulting in increased analysis demand. The gold-standard chromatographic techniques continue to be employed for most laboratory analyses. However, they made only modest gains productivity over years, these are primarily due automated sample preparation injection. Alternatively, significant VOC through faster reduced instrument maintenance could achieved by adopting direct mass spectrometry such as selected ion flow tube (SIFT-MS). This article demonstrates that routine quality control checks, method validation, standard additions, internal standards readily applied SIFT-MS, simplifying adoption technique. addition, workflows chromatographically challenging species simplified using SIFT-MS. Sample throughputs two- 25-fold depending on analytical procedure.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volatile generation in bell peppers during frozen storage and thawing using selected ion flow tube mass spectrometry (SIFT-MS).

UNLABELLED To determine volatile formation during storage and thawing, whole, pureed, blanched, and raw green and red bell peppers (Capsicum annuum) were frozen quickly or slowly then stored at -18 °C for up to 7 mo, with and without SnCl(2) addition during thawing. Headspace analysis was performed by a Selected Ion Flow Tube Mass Spectrometer (SIFT-MS). After blanching, (Z)-3-hexenal had a lar...

متن کامل

Selected Tandem Mass Spectrometry Ion

1 Selected tandem mass spectrometry (MS/MS) ion monitoring (SMIM) is the most 2 suitable scanning mode to detect known peptides in complex samples when an ion-trap 3 mass spectrometer is the instrument used for the analysis. In this mode, the MS detector 4 is programmed to perform continuous MS/MS scans on one or more selected 5 precursors, either during a selected time interval, or along the w...

متن کامل

Selected ion flow tube mass spectrometry for on-line trace gas analysis in biology and medicine.

Selected ion flow tube mass spectrometry, (SIFT-MS), is a technique for simultaneous real-time quantification of several trace gases in air and exhaled breath. It relies on chemical ionization of the trace gas molecules in air/breath samples introduced into helium carrier gas, using H(3)O(+), NO(+) and O(2)(+) reagent (precursor ions). Reactions between the precursor ions and the trace gas mole...

متن کامل

Direct detection and quantification of malondialdehyde vapour in humid air using selected ion flow tube mass spectrometry supported by gas chromatography/mass spectrometry.

RATIONALE It has been proposed that malondialdehyde (MDA) reflects free oxygen-radical lipid peroxidation and can be useful as a biomarker to track this process. For the analysis of MDA molecules in humid air by selected ion flow tube mass spectrometry (SIFT-MS), the rate coefficients and the ion product distributions for the reactions of the SIFT-MS reagent ions with volatile MDA in the presen...

متن کامل

Alkylpyrazines and other volatiles in cocoa liquors at pH 5 to 8, by Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS).

UNLABELLED Cocoa beans were alkalized before or after roasting and made into cocoa liquor before analyzing by SIFT-MS. In both alkalized-before-roasting and alkalized-after-roasting samples, there were significantly higher concentrations of alkylpyrazines for the samples with pH above 7 than pH below 7. At pH 8, the concentrations of 2,3-, 2,5-, and 2,6-dimethylpyrazine (DMP), 2,3,5-trimethylpy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Reviews in separation sciences

سال: 2021

ISSN: ['2589-1677']

DOI: https://doi.org/10.17145/rss.21.003