Applicability of a Sensitivity-enhanced Quartz Crystal Microbalance in Analyzing Blood Plasma Viscosity and Coagulation
نویسندگان
چکیده
منابع مشابه
Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor
A quartz crystal microbalance (QCM) biosensor with nanogram sensitivity has been constructed through a reasonable designing and biological processing of the piezoelectric quartz crystals. Due to its highly sensitivity, real time detection and low cost, the proposed QCM biosensor has a promising potential in blood coagulation research. In the current study, the QCM biosensor was used to determin...
متن کاملDetection of folate binding protein with enhanced sensitivity using a functionalized quartz crystal microbalance sensor.
In this report, we describe the development of a quartz crystal microbalance biosensor for detection of folate binding protein (FBP). Using a simple folate-BSA conjugate adsorbed onto a Au-coated quartz sensor, a detection limit of 30 nM was achieved. Binding of FBP to the sensor surface could be blocked at concentrations as high as 1 microM with a 100-fold excess of folic acid, indicating the ...
متن کاملQuartz Crystal Microbalance in Cell Biology Studies
ISSN: 2153-0777 JBTC, an open access journal Label-Free Biosensor Cell Assays J Biochip Tissue Chip
متن کاملNoise Measurement Setup for Quartz Crystal Microbalance
Quartz crystal microbalance (QCM) is a high sensitive chemical sensor which has found widespread spectrum of applications. There are several mechanisms that are related to fluctuation phenomena. Since the aim of our research is oriented to study the sensitivity and influence of different kind of noises on sensor resolution, we modified an existing method to measure the small frequency fluctuati...
متن کاملA Practical Model of Quartz Crystal Microbalance in Actual Applications
A practical model of quartz crystal microbalance (QCM) is presented, which considers both the Gaussian distribution characteristic of mass sensitivity and the influence of electrodes on the mass sensitivity. The equivalent mass sensitivity of 5 MHz and 10 MHz AT-cut QCMs with different sized electrodes were calculated according to this practical model. The equivalent mass sensitivity of this pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors and Materials
سال: 2022
ISSN: ['0914-4935', '2435-0869']
DOI: https://doi.org/10.18494/sam3774