Appearance of Chance Coincidence in Attenuation Measurements Carried out by using Coincidence Technique
نویسندگان
چکیده
The appearance of chance coincidence in attenuation measurements using technique is investigated. A two 3"*3" NaI(Tl) detector spectrometer with 0.5 μ Ci Na-22 source were used. Two different materials forms, namely mixed metallic powders and Fe-sheets are ratio counts to total real coincidences annihilation peak had ranged between (0.007-0.013) (0.011-0.036) for the thicknesses mentioned respectively. linear coefficients due at 1274keV 0.1 0.38 cm-1 assuring proportionality energy. When treated as being "lost" from added again latter, no change observed coefficient that calculated before taking accidental into consideration.
منابع مشابه
Measuring Electron Response in NaI(Tl) using Compton Coincidence Technique
The scintillation efficiency of electron recoils in liquid xenon (LXe) is not well measured at low energies. The Compton coincidence technique (CCT) is set up using a NaI(Tl) detector and HPGe detector to measure the energy dependence of the light yield in the NaI(Tl) detector from which we can extract the scintillation effieciency. This technique allows for the detection of low energy electron...
متن کاملA beta-ray spectrometer for coincidence measurements
An intermediate image beta-ray spectrometer has been constructed utilizing the focusing properties of a Ushaped magnetic field distribution. The construction and performance of the instrument are discussed. A transmission of ten percent has been attained with a resolution of about six percent. A scintillation spectrometer is used in conjunction with the intermediate image spectrometer for the p...
متن کاملGamma-gamma Coincidence Overlap Coincidence Method for Measuring Gamma-gamma Coincidence of Na Radiation Safety
RADIATION SAFETY The radioactive sources used in this experiment are only a few microcuries in strength, and they are all sealed, so they actually pose no significant health hazard. However we will follow good safety procedure. Horseplay involving the sources is forbidden. While the sources are not dangerous, like any radioactive source they should be treated with respect and properly handled. ...
متن کاملThe importance of attenuation correction for coincidence positron tomography on hybrid PET/SPECT gamma camera system
Abstract is NOT available
متن کاملGe(Li)-Ge(Li) coincidence measurements in 132Xe
2014 Gamma-gamma coincidence measurements were carried out on the decay of 132I with two Ge(Li) detectors and a two parameter system. Several new transitions were observed. From these results, 18 new levels at 2 167.3, 2 187.4, 2 303.6, 2 916.9, 2 935.6, 2 959.1, 3 076.4, 3 112.1,3 122.3,3 155.4, 3 192.8, 3 214.3, 3 226.8, 3 237.4, 3 260.0, 3 319.6, 3 354.0, and 3 385.1 keV were placed in the 1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Ma?alla? Tikr?t li-l-?ul?m al-?irfa?
سال: 2022
ISSN: ['2415-1726', '1813-1662']
DOI: https://doi.org/10.25130/tjps.v26i1.104