Aortic regurgitation during continuous-flow left ventricular assist device support: An insufficient understanding of an insufficient lesion
نویسندگان
چکیده
منابع مشابه
Aortic regurgitation during systolic-phase accompanied by mitral regurgitation in patients with continuous-flow left ventricular assist device.
results along with previous studies by the same group are relevant to the scientific community for several reasons. Three-dimensional echocardiography and software developments open a new field of research on cardiac physiology and pathological conditions previously limited to experimental animal models. Continuous development of new therapeutic surgical and interventional devices challenges no...
متن کاملPathology of aortic valve remodeling after continuous-flow left ventricular assist device support.
Affiliations: Department of Pathology, University Medical Center Utrecht, Utrecht, The Netherlands Department of Cardiothoracic Surgery, University Medical Center Utrecht, Utrecht, The Netherlands Department of Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands Department of Cardiothoracic Surgery, University Medical Center Utrecht, Utrecht, The Netherlands, at present work...
متن کاملLeft ventricular assist device-related systolic aortic regurgitation.
A 39-year-old woman underwent transesophageal echocardiography during heart transplantation after 2.5 years of support with a continuous-flow left ventricular assist device (cf-LVAD). The patient was admitted to the hospital when a donor heart became available, and did not present with any symptoms or signs of heart failure on cf-LVAD support. Color-flow imaging demonstrated pronounced systolic...
متن کاملAortic regurgitation after left ventricular assist device placement.
A 1 60-YEAR-OLD man with a history of recent heart failure caused by both primitive and ischemic dilated cardiomypathy underwent the successful implantation of a left ventriclar assist device (Novacor LVAS; WorldHeart, Ottawa, ON, anada) under cardiopulmonary bypass. Intraoperative transsophageal echocardiography (TEE) performed immediately fter implantation showed the correct placement of both...
متن کاملLeft ventricular-assist device arrest: total thrombosis of a continuous flow left ventricular-assist device.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . doi:10.1093/ehjci/jev290 Online publish-ahead-of-pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Heart and Lung Transplantation
سال: 2016
ISSN: 1053-2498
DOI: 10.1016/j.healun.2016.06.006