Anterolateral Intermuscular Approach for Type A2 Intertrochanteric Fractures: A Cadaveric Study
نویسندگان
چکیده
منابع مشابه
Anterolateral approach for tibial pilon fractures.
The anterolateral approach to the tibia has been popularized for management of tibial pilon fractures. This approach offers the benefit of improved soft tissue coverage and the potential for a lower rate of wound-healing complications by avoiding incision placement over the subcutaneous border of the tibia. Although the fracture pattern dictates specific plate use, antomically designed anterola...
متن کاملSurgical anatomy of the diaphragm in the anterolateral approach to the spine: a cadaveric study.
STUDY DESIGN Laboratory cadaveric study. OBJECTIVE To delineate the pertinent surgical anatomy of the diaphragm during access to the anterolateral thoracolumbar junction. SUMMARY OF BACKGROUND DATA The general anatomy of the thoracic diaphragm is well described. The specific surgical anatomy as it pertains to the lateral and thoracoabdominal approaches to the thoracolumbar junction is not w...
متن کاملThe Comparison of Compression Hip Screw and Bipolar Hemiarthroplasty for the Treatment of AO Type A2 Intertrochanteric Fractures
PURPOSE The purpose of this study was to compare the outcomes of osteosynthesis using compression hip screw fixation versus bipolar hemiarthroplasty in AO type A2 intertrochanteric fractures. MATERIALS AND METHODS From March 2003 to December 2009, 89 patients were included in this study. They were treated using compression hip screws (43 cases) or bipolar hemiarthroplasty (46 cases). The mean...
متن کاملComplications of cement-augmented dynamic hip screws in unstable type intertrochanteric fractures--a case series study.
BACKGROUND Polymethylmethacrylate (PMMA) cement-augmented dynamic hip screws (DHS) have been used as a solution in unstable intertrochanteric fractures (ITF). Our aim was to investigate the complications in PMMA cement-augmented DHS. METHODS All patients who had received DHS plate osteosynthesis with or without PMMA cement augmentation from August 2005 to July 2009 in one medical center were ...
متن کاملType II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)
Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Surgery
سال: 2015
ISSN: 0020-8868,2520-2456
DOI: 10.9738/intsurg-d-14-00188.1