Anterior segment optical coherence tomography imaging and histopathologic findings of an overhanging filtering bleb
نویسندگان
چکیده
منابع مشابه
correlation between filtering bleb clinical morphology, anterior segment optical coherence tomography findings, and intraocular pressure
purpose : to evaluate usefulness of anterior segment optical coherence tomography (as-oct) in evaluation of filtering bleb functionality and to correlate its findings with clinical bleb examination methods : in this cross-sectional, descriptive study 55 eyes with apparently functional bleb were evaluated. following a comprehensive ophthalmic examination, filtering bleb grading was performed bas...
متن کاملAnterior Segment Optical Coherence Tomography Imaging of Central Toxic Keratopathy.
The authors report anterior segment optical coherence tomography (OCT) imaging findings in a case of central toxic keratopathy following laser in situ keratomileusis (LASIK) surgery for low hyperopia. OCT imaging 1 month after surgery demonstrates that the flap thickness is maintained and the location of stromal tissue loss is just posterior to the flap in the stromal bed in the affected area. ...
متن کاملAnterior Segment Optical Coherence Tomography Imaging of Conjunctival Filtering Blebs after Glaucoma Surgery
Time domain (TD) and spectral domain (SD) optical coherence tomography (OCT) are cross-sectional, noncontact, high-resolution diagnostic modalities for posterior and anterior segment (AS) imaging. The AS-OCT provides tomographic imaging of the cornea, iris, lens, and anterior chamber (AC) angle in several ophthalmic diseases. In glaucoma, AS-OCT is utilized to evaluate the morphology of AS stru...
متن کاملAnterior Segment Time Domain Optical Coherence Tomography
To compare anterior segment parameters using quantitative imaging by anterior segment time domain optical coherence tomography (AS-OCT) and high frequency ultrasound biomicroscopy (HF-UBM). SETTING: Department of Ophthalmology at Bari University. METHODS: Seventy-two eyes of 72 subjects had anterior segment evaluation by AS-OCT (Stratus ver 6Zeiss) and HF-UBM (OTI-Scan HF35-50). Central corneal...
متن کامل[Anterior segment optical coherence tomography in glaucoma].
In recent years, the rapid development of diagnostic optic devices has generated optical coherence tomography (OCT) as a new, non-invasive diagnostic method. With technical progress of the infrared spectrum at 1,310 nm, OCT of the anterior segment also became feasible. With anterior segment OCT different examinations which so far were ruled out by ultrasound in contact manner could be executed ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Eye
سال: 2008
ISSN: 0950-222X,1476-5454
DOI: 10.1038/eye.2008.166