Ant^|^apos;s Nest Corrosion on Copper Tube in Formic Acid Solution

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corrosion and Inhibition Studies of Copper in Aqueous Solutions of Formic Acid and Acetic Acid

Corrosion behaviour of copper has been investigated in different compositions of formic acid and acetic acid at 30°C by a potentiostatic method. The maximum corrosion rate was found in 2&40mol/o formic acid and in 20 mol/o acetic acid in aqueous solution mixtures. The corrosion rate depended on the concentration of either acid. Formic acid is observed to be more corrosive than acetic acid. The ...

متن کامل

Developing of Corrosion Resistance Nano Copper Oxide Coating on Copper using Anodization in Oxalate solution

Copper alloys are widely used in the manufacturing of heat transfer applications, this due to their excellent heat transfer properties. Copper contamination is one of the serious industrial problems in the boiler feed water system. This contamination commonly resulted from copper corrosion reactions in boiler feed water environment. The best way to reduce the copper contamination is by improvin...

متن کامل

Investigation of Furfural as Corrosion Inhibitor in Hydrochloric Acid Solution

Effectiveness of furfural as an organic inhibitor in 5 percent hydrochloric acid which is used in acid pickling of steel was evaluated. Lungmuir, Frumkin and Flory-Huggins isotherms [1, 2] were used to determine the parameters of effective adsorption, free energy and entropy of adsorption. Furfural indicated an inhibition less than 17 percent in concentrations of 0.001 mole per liter for a dura...

متن کامل

Investigation of Furfural as Corrosion Inhibitor in Hydrochloric Acid Solution

Effectiveness of furfural as an organic inhibitor in 5 percent hydrochloric acid which is used in acid pickling of steel was evaluated. Lungmuir, Frumkin and Flory-Huggins isotherms [1, 2] were used to determine the parameters of effective adsorption, free energy and entropy of adsorption. Furfural indicated an inhibition less than 17 percent in concentrations of 0.001 mole per liter for a dura...

متن کامل

Corrosion behaviour of mild steel in aqueous acetic acid solutions containing different amounts of formic acid

The kinetics of mild steel corrosion in 20:0, 19:1, 18:2 and 15:5 (v/v%) aqueous mixture of acetic and formic acids has been investigated by weight loss and potentiostatic polarization techniques. The effects of composition of electrolyte and temperature on the corrosion rate of mild steel have been evaluated. The corrosion rate of mild steel increased linearly with temperature as well as amoun...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Zairyo-to-Kankyo

سال: 2012

ISSN: 0917-0480,1881-9664

DOI: 10.3323/jcorr.61.389