Another Disinfectant for Enterococci
نویسندگان
چکیده
منابع مشابه
What must be done to prevent another humidifier disinfectant disaster?
The humidifier disinfectant disaster (HDD) was not a simple poisoning accident by biocides, but a singular disaster in history created by chemicals in household products. This disaster was a result of the failure of a system for the management of chemical and product safety. Since the management authority for chemical usage safety is different from those for chemical safety in products, many bl...
متن کاملFormalin disinfectant unit for incubators.
Most infants admitted to premature baby or neonatal surgical units are nursed in incubators during part of their stay in hospital. There are many advantages of nursing these infants in incubators, but there is also one great disadvantage, the danger of bacterial colonization and contamination inside the incubator. The temperature inside the incubator approaches that of the body and many of thes...
متن کاملFormalin Disinfectant Unit for Incubators
Most infants admitted to premature baby or neonatal surgical units are nursed in incubators during part of their stay in hospital. There are many advantages of nursing these infants in incubators, but there is also one great disadvantage, the danger of bacterial colonization and contamination inside the incubator. The temperature inside the incubator approaches that of the body and many of thes...
متن کاملDisinfectant Treatment of Cholera
or uncombined, is beneficial in cholera. In the case under notice the black oxide of manganese was not used, therefore the gas obtained, I should have mentioned, was hydrochloric acid and not chlorine. Had black oxide of manganese been available at the time, it would have been employed, for the element in an uncombined form would be more potent than in a combined form. The carbonate of soda was...
متن کاملA new disinfectant.
Qualitative and quantitative tests have been carried out to assess the value of Cidex(1), a glutaraldehyde solution, as a disinfectant. Most of the tests were qualitative and were carried out in conditions as closely resembling those found in hospital practice as possible. Recently used anaesthetic equipment, catheters, and a cystoscope, which had been artificially contaminated with suspensions...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Infection Control & Hospital Epidemiology
سال: 1999
ISSN: 0899-823X,1559-6834
DOI: 10.1086/503133