Anodic Stripping Voltammetry of Nickel Ion Using a Rotating Plastic Formed Carbon Electrode
نویسندگان
چکیده
منابع مشابه
Determination of Copper in Wine by Anodic Stripping Voltammetry with Rotating Glassy Carbon and Microfiber Carbon Electrode
Anodic stripping voltammetry (ASV) with rotating glassy carbon electrode (RGCE) and microfiber carbon electrode (μFCE), both filmed with mercury, were used to determine copper content in wine. Influence of phenolics on in situ mercury film formation was studied. Wine and quercetin were added gradually into solution of Hg(II) in acetic acid-sodium acetate buffer (pH = 4.60). Reduction of Hg(II) ...
متن کاملDetermination of mercury at a dithizone-modified glassy carbon electrode by anodic stripping voltammetry.
متن کامل
Ultra-Sensitive Anodic Stripping Voltammetry for the Determination of Xanthine at a Glassy Carbon Electrode
An electrochemical anodic stripping procedure for ultra-trace assay of xanthine in Cu2þ solution at a glassy carbon electrode (GCE) is described. Cyclic voltammetry was used to characterize the nature of the process taking place at the GCE. The anodic stripping response in the presence of Cu2þ, at 150 mV (peak I) and 600 mV (peak II), is evaluated with respect to various experimental and instru...
متن کاملAnodic stripping voltammetry of lead and cadmium using a mercury ®lm electrode and thiocyanate
It is well known that lead and cadmium can be determined with good sensitivity using anodic stripping voltammetry (ASV) and a mercury ®lm electrode. However, the mercury ®lm formation is poorly reproducible and cannot fully be removed electrochemically. We have evaluated procedures to improve the reproducibility and sensitivity of the ASV method and found that in the presence of thiocyanate the...
متن کاملMercury-free anodic stripping voltammetry of lead ions using a PVS-doped polyaniline modified glassy carbon electrode
The advent of stripping voltammetry has improved the performance of analytical voltammetry to a considerable extent.1 The enhanced sensitivity and lower detection limits can be achieved in this technique by enrichment of the analyte prior to voltammetric determination. The common enrichment processes include reduction of metal ions through formation of metal films or amalgams, reductive or oxid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 2020
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.69.585