Anodic Stripping Voltammetry of Nickel Ion Using a Rotating Plastic Formed Carbon Electrode

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Copper in Wine by Anodic Stripping Voltammetry with Rotating Glassy Carbon and Microfiber Carbon Electrode

Anodic stripping voltammetry (ASV) with rotating glassy carbon electrode (RGCE) and microfiber carbon electrode (μFCE), both filmed with mercury, were used to determine copper content in wine. Influence of phenolics on in situ mercury film formation was studied. Wine and quercetin were added gradually into solution of Hg(II) in acetic acid-sodium acetate buffer (pH = 4.60). Reduction of Hg(II) ...

متن کامل

Ultra-Sensitive Anodic Stripping Voltammetry for the Determination of Xanthine at a Glassy Carbon Electrode

An electrochemical anodic stripping procedure for ultra-trace assay of xanthine in Cu2þ solution at a glassy carbon electrode (GCE) is described. Cyclic voltammetry was used to characterize the nature of the process taking place at the GCE. The anodic stripping response in the presence of Cu2þ, at 150 mV (peak I) and 600 mV (peak II), is evaluated with respect to various experimental and instru...

متن کامل

Anodic stripping voltammetry of lead and cadmium using a mercury ®lm electrode and thiocyanate

It is well known that lead and cadmium can be determined with good sensitivity using anodic stripping voltammetry (ASV) and a mercury ®lm electrode. However, the mercury ®lm formation is poorly reproducible and cannot fully be removed electrochemically. We have evaluated procedures to improve the reproducibility and sensitivity of the ASV method and found that in the presence of thiocyanate the...

متن کامل

Mercury-free anodic stripping voltammetry of lead ions using a PVS-doped polyaniline modified glassy carbon electrode

The advent of stripping voltammetry has improved the performance of analytical voltammetry to a considerable extent.1 The enhanced sensitivity and lower detection limits can be achieved in this technique by enrichment of the analyte prior to voltammetric determination. The common enrichment processes include reduction of metal ions through formation of metal films or amalgams, reductive or oxid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BUNSEKI KAGAKU

سال: 2020

ISSN: 0525-1931

DOI: 10.2116/bunsekikagaku.69.585