Annual Inhalation Dose of Indoor Radon and Thoron in Mizoram, India

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurements of indoor radon, thoron and their progeny in Farrukhabad city of Uttar Pradesh, India

Background: More than 50% of the total dose received by human beings from all sources of radiation (both from natural and manmade) comes from radon and its progeny which is responsible for lung cancer in many cases. Materials and Methods: In the present study, the measurements have been carried out by using twin chamber dosimeter cups with LR-115 type-II detectors. The value of track ...

متن کامل

Inhalation Dose Due to Indoor Radon

The Rn and Rn enter the atmosphere mainly by crossing the air interface of either soil-air or building materials. The existence of relatively high indoor concentration maintains a large Rn, Rn concentration gradient between the materials and open air. The present paper deals with the experimental measurement of Rn, Rn concentrations and the associated inhalation dose rates due to them in the dw...

متن کامل

Measurements of indoor radon, thoron and their progeny in Farrukhabad city of Uttar Pradesh, India

*Corresponding author: Mr. Deepak Verma, Department of Applied Physics, Z. H. College of Engineering & Technology, Aligarh Muslim University, Aligarh-202002, Uttar Pradesh, India. Fax: +91 571 270042 E-mail: [email protected] Background: More than 50% of the total dose received by human beings from all sources of radiation (both from natural and manmade) comes from radon and its progeny which is...

متن کامل

measurements of indoor radon, thoron and their progeny in farrukhabad city of uttar pradesh, india

background: more than 50% of the total dose received by human beings from all sources of radiation (both from natural and manmade) comes from radon and its progeny which is responsible for lung cancer in many cases. materials and methods: in the present study, the measurements have been carried out by using twin chamber dosimeter cups with lr-115 type-ii detectors. the value of track density of...

متن کامل

Study of Indoor Radon and Thoron Levels in Srirampura, Bangalore, India using Passive Detector Technique

Results of the measurement of indoor radon and thoron carried out in and around Srirampura, Bangalore, India using passive detector technique is presented. Measurements were carried out using twin cup radon-thoron dosimeter using small strips of 12 micron thick LR-115 Type II nuclear track detectors. Measurements were carried out in 60 dwellings for a period of one year on a quarterly time inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Research & Development in Material Science

سال: 2021

ISSN: 2576-8840

DOI: 10.31031/rdms.2021.15.000852