منابع مشابه
Anisocoria after use of dermatological product
DOI: 10.1590/S1679-45082017AI4040 A 45-year-old woman sought ophthalmologic care complaining about a sudden visual acuity on her right eye and anisocoria. She denied previous comorbidities and traumas. Upon examination, her ocular motility was normal and no ptosis was seen. Slit-lamp biomicroscopy and fundoscopy exams were normal. The mydriasis of the right eye, with consensual light reflex of ...
متن کاملTransient Anisocoria after Corneal Collagen Cross-Linking
Purpose. To report a case with transient anisocoria after corneal collagen cross-linking (CXL). Methods. Case report. Results. A 24-year-old male underwent corneal collagen cross-linking (CXL) in his right eye for keratoconus. At the end of the procedure, the pupil of the treated eye was irregular and dilated, while the pupil of the fellow eye was round, regular, and reactive (anisocoria). The ...
متن کاملSevere Anisocoria after Oral Surgery under General Anesthesia
INTRODUCTION Anisocoria indicates a difference in pupil diameter. Etiologies of this clinical manifestation usually include systemic causes as neurological or vascular disorders, and local causes as congenital iris disorders and pharmacological effects. CASE REPORT We present a case of a 47-year-old man, suffering from spastic tetraparesis. After the oral surgery under general anesthesia, the...
متن کامل[Everyday anisocoria: anisocoria epidemiology in a secondary care setting].
OBJECTIVE [corrected] To determine the relative importance of the different forms of anisocoria in a General Hospital. METHODS A prospective, longitudinal study was conducted including all patients referred for this reason to the Neuro-Ophthalmology Unit of the Henares University Hospital, Madrid (Spain), from November 2008 to October 2011. The differences in pupil diameter were studied under...
متن کاملTransient anisocoria in a migraineur.
EVALUATING THE “PROBLEM PUPIL” Clinical History.— A 43-year-old woman presented for evaluation of transient anisocoria. Eleven days previously on awakening in the morning, she noted that the right pupil was larger than the left and that she had trouble focusing. About 4 hours later, she saw an optometrist who found the right pupil to be 3 mm in bright light and 6 mm in dim light and the left pu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Canadian Anaesthetists’ Society Journal
سال: 1985
ISSN: 0008-2856,1496-8975
DOI: 10.1007/bf03011355