We measured angular-resolved diffuse reflectance in tissue samples of different anisotropic characteristics. Experimental measurements were compared with theoretical results based on the diffusion approximation. The results indicated that the angular distribution in isotropic tissue was the same as in isotropic phantoms. Under normal incidence, the measured angular profiles of diffuse reflectan...
متن کاملDIFFUSE REFLECTANCE MEASUREMENTS FROM DIFFERENT SURFACES
Relative diffuse reflection measurements from the original and ground surfaces using a He-Ne laser are reported. The intensity measurements for the metallic, transparent dielectric, matte plastic surfaces and colored papers are presented. Our results indicate that among metallic surfaces tested, aluminum has the highest diffuse reflectance; while the original stainless steel surface shows the l...
متن کاملSpectral and geometrical variation of the bidirectional reflectance distribution function of diffuse reflectance standards.
A study on the variation of the spectral bidirectional reflectance distribution function (BRDF) of four diffuse reflectance standards (matte ceramic, BaSO(4), Spectralon, and white Russian opal glass) is accomplished through this work. Spectral BRDF measurements were carried out and, using principal components analysis, its spectral and geometrical variation respect to a reference geometry was ...
متن کاملQuantitative Diffuse Reflectance Spectroscopy
In the field of biomedical optics, diffuse reflectance spectroscopy (DRS) is a frequently used technique for obtaining information about the optical properties of the medium under investigation. The method utilizes spectral difference between incident and backscattered light intensity for quantifying the underlying absorption and scattering processes that affects the light-medium interaction. I...
متن کاملSpatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue.
The absorption and transport scattering coefficients of biological tissues determine the radial dependence of the diffuse reflectance that is due to a point source. A system is described for making remote measurements of spatially resolved absolute diffuse reflectance and hence noninvasive, noncontact estimates of the tissue optical properties. The system incorporated a laser source and a CCD c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Optics
سال: 2007
ISSN: 0003-6935,1539-4522
DOI: 10.1364/ao.46.006552