ANATOMICAL AND FUNCTIONAL OUTCOME OF COMMINUTED INTRA-ARTICULAR DISTAL RADIAL FRACTURES TREATED WITH VOLAR BUTTRESS PLATING AND ANTI-IMPACTION KIRSCHNER WIRE THROUGH THE RADIAL STYLOID

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined volar and dorsal plating for complex comminuted distal radial fractures.

PURPOSE To review outcomes of combined volar and dorsal locked plating for AO type-C3 complex comminuted distal radial fractures. METHODS Records of 24 patients aged 17 to 77 (mean, 53.3) years who underwent combined volar and dorsal locked plating for AO type-C3 distal radial fractures with volar and dorsal metaphyseal and intra-articular comminution were reviewed. 21 were closed fractures, ...

متن کامل

Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating technique

BACKGROUND A possible difficulty in intra-articular fracture of the distal radius is the displacement tendency of the radial styloid process due to the tension of the brachioradialis tendon. METHODS Ten patients treated within one year for complex distal radius fractures by double-plating technique with a radial buttress plate and volar locking plate, through a single volar approach, were fol...

متن کامل

Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model

BACKGROUND The locking screws target the radial styloid, theoretically provide greater stability against radial styloid fragment. However, it is unknown whether the radial styloid locking screws increased the stability of the volar plating system fixation along the entire distal radius or not. In this study, we evaluated the stability of the volar plating system fixation with or without the rad...

متن کامل

Acutrak fixation of comminuted distal radial fractures.

The authors describe a new technique of fixation of comminuted displaced distal radial fractures in young adults. A 40-year-old man fell from a ladder and injured his wrist. He sustained a comminuted fracture of the distal radius. The fracture was opened through a volar incision and the three rotated, unreduced fragments were reduced and fixed with three Acutrak (Acumed Inc., Beaverton, OR, USA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Evolution of Medical and Dental Sciences

سال: 2018

ISSN: 2278-4748,2278-4802

DOI: 10.14260/jemds/2018/458