Analysis on Electromagnetic Environment from 750 kV Transformer Substation in Gansu Power Network

نویسندگان

چکیده

Abstract In order to understand the influence of 750 kV power transmission and transformation project on electromagnetic radiation surrounding environment, data electric field intensity, magnetic intensity noise from substation equipment system in some areas Gansu Province were monitored analyzed. The results showed that near circuit breaker, switch reactance main producing high intensity. breaker is highest equipment, with average value 12.40 ± 1.25 kV/m, while area reactor. study could provide scientific basis for environmental assessment prevention ultrahigh voltage projects.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

analysis of power in the network society

اندیشمندان و صاحب نظران علوم اجتماعی بر این باورند که مرحله تازه ای در تاریخ جوامع بشری اغاز شده است. ویژگیهای این جامعه نو را می توان پدیده هایی از جمله اقتصاد اطلاعاتی جهانی ، هندسه متغیر شبکه ای، فرهنگ مجاز واقعی ، توسعه حیرت انگیز فناوری های دیجیتال، خدمات پیوسته و نیز فشردگی زمان و مکان برشمرد. از سوی دیگر قدرت به عنوان موضوع اصلی علم سیاست جایگاه مهمی در روابط انسانی دارد، قدرت و بازتولید...

15 صفحه اول

Power-frequency magnetic field calculation around an indoor transformer substation

The authors propose a full three-dimensional (3D) calculation model based on a multipole technique able to predict the magnetic field pollution outside of indoor medium voltage/low voltage (MV/LV) transformer substations. The authors demonstrate that the proposed model may be advantageously used in all problems related to the characterization of the electromagnetic environment around a MV/LV tr...

متن کامل

Electric and Magnetic Field Computation of 35 Kv Voltage Level of Transformer Substation 35/10 Kv Using the Cdegs Software

Paper presents electric and magnetic field computation of 35 kV voltage level of transformer substation 35/10 kV using CDEGS software. Based on well known theoretical considerations of electric and magnetic fields, a realistic simulation model of transformer station 35/10 kV was develop. All calculations are made for horizontal plane with height of 1,5 m above the soil changing coordinates alon...

متن کامل

Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IOP conference series

سال: 2021

ISSN: ['1757-899X', '1757-8981']

DOI: https://doi.org/10.1088/1755-1315/687/1/012011