اندیشمندان و صاحب نظران علوم اجتماعی بر این باورند که مرحله تازه ای در تاریخ جوامع بشری اغاز شده است. ویژگیهای این جامعه نو را می توان پدیده هایی از جمله اقتصاد اطلاعاتی جهانی ، هندسه متغیر شبکه ای، فرهنگ مجاز واقعی ، توسعه حیرت انگیز فناوری های دیجیتال، خدمات پیوسته و نیز فشردگی زمان و مکان برشمرد. از سوی دیگر قدرت به عنوان موضوع اصلی علم سیاست جایگاه مهمی در روابط انسانی دارد، قدرت و بازتولید...
15 صفحه اولMagneto-thermal finite element modeling of 2nd generation HTS for FCL design purposes
Coated conductors are very promising for the design of novel and efficient Fault Current Limiter (FCL). However, before considering using them in a power grid, their thermal and electromagnetic behaviors in the presence of over-critical currents need to be investigated in details. In this context, we performed finite element magneto-thermal modeling of coated conductors under over-critical curr...
متن کاملContingency Analysis of Reduced 220 Kv Kptcl System Using Mat-lab Simulink Model
In the modern days the power system is becoming wide and complex. Contingency Analysis (CA) is critical in power system analysis. Due to the tremendous and yet increasing amount of data computed by CA, effective visualizations are needed to present the CA results to assist the system operators and engineers to comprehend the static security status of the system in a quick and intuitive manner. ...
متن کاملTechnical and Economical Impacts on a Power System by Introducing an HTS FCL
Fault current limiters (FCLs) can be considered as key elements in power systems using high temperature superconductors. This analysis takes into account the system benefits provided by the introduction of FCLs in various network configurations. New meshing possibilities, alternative grounding method and increase of power transmission are highlighted. It is the desire of most power system utili...
متن کاملTransient overvoltage protection: The implications of new techniques
The paper presents a comparison of the performance of voltage-switching devices and voltage-limiting devices for late seventies-vintage SPDs as marketed and installed in service panels in the USA and in Europe. Artifacts in the response of a typical oscilloscope to a nearby gap sparkover, and the effect of lead dress inside the panels and outdoor installation are described. Predictably, the per...