ANALYSIS OF REINFORCED CONCRETE COLUMNS FITTED INSIDE STEEL CASINGS

نویسندگان

چکیده

Due to construction costs and operational issues have been in this study discuss how strengthen the concrete columns. The results of previous studies on some structures earthquake-prone weakness reinforced inside steel casings surrounding columns is a modern technique used many countries today for rectangular circular concrete. advantages method convenient, economical easy. Reference model column without casing others were wrapped amount retrofitting, which has approved changing thickness cover are main variable research. Were analyzed under effect axial force using finite element by program ANSYS (version 11). showed that increase susceptibility bearing inflicted largest form casing, as well leads increased endurance.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic Behavior of Steel Reinforced Concrete Beam-Columns and Frames

The ability to perform accurate nonlinear simulations is a key component in the assessment of the behavior of seismic force resisting systems. A three-dimensional distributed plasticity formulation for composite beam-columns suitable for nonlinear static and dynamic analyses of composite seismic force resisting systems has been developed. New uniaxial constitutive relations are developed for th...

متن کامل

Rehabilitation of Reinforced Concrete Columns

In recent years, rehabilitation has been the subject of extensive research due to increased spending on building work and repair of built works. In all cases, it is absolutely essential to carry out methods of strengthening or repair of structural elements, and that following an inspection analysis and methodology of a correct diagnosis. The reinforced concrete columns are important elements in...

متن کامل

Seismic Response of Reinforced Concrete Columns

There are a large number of reinforced concrete buildings in seismically active areas of the world that are not built in accordance with modern seismic design provisions such as those published by American Concrete Institution ([ACI] Committee 318, 2008). In the United States and other parts of the developed world, these buildings were constructed between 1930s to mid 1970s according to the bui...

متن کامل

Temperature Field Calculation and Analysis within Steel Tube Reinforced Columns

The temperature field analysis method of steel tube reinforced columns under fire by finite element analysis software ABAQUS is proposed in this paper. The theoretical method is validated by tests, and the calculated results agree well with those of tests. On the basis of that, the influencing laws of temperature rising time; section perimeter; steel reinforcement ratio and sectional core area ...

متن کامل

Reinforced Concrete Columns in Torsion (RESEARCH NOTE).

ACT does not suggest any regulations for columns under torsion. However, by all means, the number of such columns used in steel and concrete structures is abundant. In this paper, using the results of laboratory tests on 35 square and rectangular columns with intermediate slender ratios, relations for determination of torsional strengths of reinforced concrete under axial compression have been ...