Analysis of partial discharge signals from generator propagation in excitation transformer by EMTP

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Method for Extracting Partial Discharge Signals in Transformer Winding with Wavelet Analysis

In this paper a method for extracting Partial Discharge (PD) signals is introduced, which is implemented for evaluating electrical measured partial discharges on a 66 kV / 25 MVA fully interleaved winding of a power transformer. Applying wavelet transform to a signal produces a wavelet detail coefficient distribution throughout the time-scale, which depends on the mother wavelet chosen. This me...

متن کامل

Detection of Electrical Tree Propagation in Generator Bar Insulations by Partial Discharge Measurements

In order to detect the degradation of high voltage machine insulation, partial discharge (PD) measurements are often used. While certain defects can be identified by PD measurements a correlation between PD activity and remaining insulation life or immanent insulation failure has so far not been convincingly demonstrated. As former investigations show, the main electrical degradation process of...

متن کامل

On the Feasibility of Gap Detection of Power Transformer Partial Discharge UHF Signals: Gap Propagation Characteristics of Electromagnetic Waves

This study analyzed the transformer electromagnetic gap propagation characteristics. The influence of gap size is also analyzed, and the results experimentally verified. The obtained results indicated that the gap propagation characteristics of electromagnetic wave signals radiated by the partial discharge (PD) source in different directions are substantially different. The intensity of the ele...

متن کامل

Investigation of Partial Discharge Propagation and Location in Multiple-α and Single- Α Transformer Windings Using Optimized Wavelet Analysis

Partial discharges (PD) are recognized as the main cause of the inner insulation deterioration process in power transformers. Therefore, the optimum inner insulation design is one of the challenges a transformer designer is faced with. Transformer strength, especially during transient conditions, is a criterion for transformer insulation designers. This challenge has made designers initiate and...

متن کامل

Detection of electrical tree propagation by partial discharge measurements

The partial discharge activity during propagation of electrical treeing in epoxy resin is described. The electrical trees grew in needle-plane samples without and with an internal barrier up to the final breakdown. The simultaneous taken tree growth and discharge activity show a correlation between the propagation state of the tree and the thereby measured PD. Especially the changes in the tree...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of Engineering

سال: 2020

ISSN: 2051-3305,2051-3305

DOI: 10.1049/joe.2019.1140