ANALYSIS OF LEAKAGE CURRENT ON POLYMERIC INSULATOR UNDER RAINFOREST ENVIRONMENT

نویسندگان

چکیده

This paper develops a Finite Element Model (FEM) for 138 kV High Temperature Vulcanized (HTV) Silicone Rubber (SiR) transmission insulator in which, first step, leakage current is calculated different non-uniform continuous and discontinuous pollution deposits then features based on the phase shift between applied voltage are extracted each kind of layer to identify existence dry bands surface. A 84.75° lag was found with inserted. results evidence that angle can be used detect band formation by measuring its angle.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Insulator Contamination Forecasting Based on Fractal Analysis of Leakage Current

In this paper, an artificial pollution test is carried out to study the leakage current of porcelain insulators. Fractal theory is adopted to extract the characteristics hidden in leakage current waveforms. Fractal dimensions of the leakage current for the security, forecast and danger zones are analyzed under four types of degrees of contamination. The mean value and the standard deviation of ...

متن کامل

Impact of Pollution Location on Time and Frequency Characteristics of Leakage Current of Porcelain Insulator String under Different Humidity and Contamination Severity

One of the important factors influencing outdoor insulators performance is pollution phenomenon. The pollution, especially during humidity condition, reduces superficial resistance of insulator and lead to a flow of Leakage Currents (LC) on the insulator surface, which may result in total flashover. The LC characteristics are affected by parameters such as nature and severity of pollution. Loca...

متن کامل

Investigation of Leakage Current of Insulator Using Artificial Neural Network

DOI: 10.5281/zenodo.60115 ABSTRACT In order to improve the reliability of power transmission lines, one of the key issues is to reduce the hazard of contamination flashovers. At the present time, the most efficient way is to clean (or replace) the heavily polluted insulators. This study laboratory based tests were carried out on the model under ac voltage at different pollution levels. A new mo...

متن کامل

Leakage Current Based Thermal Modeling of Glass Disc Insulator Surface

The stability of transmission lines relies on the health of the insulators, such as glass string insulators, which may occasionally flashover during an overvoltage. The likelihood of flashover increases notably when the glass insulator is wrapped by a wet contaminant layer. In this paper a study of the surface thermal profile of glass disc insulators insulation had been carried out for both cle...

متن کامل

Improved Compressed Sensing Matrixes for Insulator Leakage Current Data Compressing

Insulator fault may lead to the accident of power network, thus the on-line monitoring of insulator is very significant. Low rates wireless network is used for data transmission of leakage current. Determination of the measurement matrix is the significant step for realizing the compressed sensing theory. This article comes up with new sparse matrices which can be used as compressed sensing mat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Foco

سال: 2023

ISSN: ['1981-223X']

DOI: https://doi.org/10.54751/revistafoco.v16n5-112