Analysis of intraocular positions of posterior implantable collamer lens by full-scale ultrasound biomicroscopy
نویسندگان
چکیده
منابع مشابه
In Vivo Positional Analysis of Implantable Collamer Lens Using Ultrasound Biomicroscopy
Purpose. To evaluate the anterior segment, the anatomical position of the implantable collamer lenses (ICL), and its relationship to adjacent ocular structures using Ultrasound Biomicroscopy (UBM). Methods. In a prospective study, 142 myopic eyes of 93 patients implanted with Visian ICL were subjected to UBM examination between March 2010 and January 2015. The relative position of ICL to the ad...
متن کاملMeasurement of the crystalline lens radius with artemis very high frequency ultrasound biomicroscopy for implantable collamer lens sizing.
To the Editor: In their recent article, Reinstein et al.1 described the use of the Artemis 2 very high frequency digital ultrasound (ArcScan, Inc., Morrison, CO) to calculate the fit of the Visian Implantable Collamer Lens (ICL). Another parameter previously proposed as influencing ICL vaulting is the crystalline lens anterior radius of curvature (ALR).2 The ALR has not yet been used in any pre...
متن کاملImplantable Collamer Lens Versus Iris-Fixed Phakic Intraocular Lens Implantation to Correct Myopia: A Meta-Analysis
This study is a meta-analysis comparing the efficacy, predictability, and safety of correcting myopia via implantation of two types of phakic intraocular lens (PIOLs): the implantable collamer lens (ICL) and iris-fixed PIOL. The Cochrane library, Pubmed, and EMBASE were searched. Study selection, data exclusion, and quality assessment were performed by two independent observers. The pooled rela...
متن کاملIntraocular pressure after implantation of the Visian Implantable Collamer Lens With CentraFLOW without iridotomy.
PURPOSE To compare the intraocular pressure (IOP) values during a 3-month period after implantation of the new Visian Implantable Collamer Lens (ICL; STAAR Surgical Company, Nidau, Switzerland) V4c design with CentraFLOW technology without iridotomy using a standard procedure followed by implantation of the conventional ICL V4b model. DESIGN Retrospective cohort study. METHODS This study in...
متن کاملImplantable collamer posterior chamber intraocular lenses: a review of potential complications.
PURPOSE To review the peer-reviewed literature reporting postoperative complications of the most recent models of Visian Implantable Collamer posterior chamber intraocular lenses (ICL, STAAR Surgical Co). METHODS A literature search of the PubMed database was performed to identify all articles related to ICL complications. Articles were obtained and reviewed to identify those that reported co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BMC Ophthalmology
سال: 2018
ISSN: 1471-2415
DOI: 10.1186/s12886-018-0783-5