Analysis of HEMP Coupling Signal for a Coaxial Cable Considering Various Cable Parameters
نویسندگان
چکیده
منابع مشابه
An Off-Center “Coaxial” Cable
A “coaxial” transmission line has inner conductor of radius a and outer conductor of radius b, but the axes of these two cylinders are offset by a small distance δ ¿ b. Deduce the capacitance and inductance per unit length, and the impedance Z, accurate to order δ/b. The (relative) dielectric constant and permeability of the medium between the two conductors both unity. The relevant frequencies...
متن کامل“Hidden” Momentum in a Coaxial Cable
Calculate the electromagnetic momentum and identify the “hidden” mechanical momentum in a coaxial cable of length L, inner radius a, outer radius b, when a battery of voltage V is connected to one end and a load resistor R0 is connected to the other. The current may be taken as uniformly distributed over the inner conductor, which has resistivity ρ. The outer conductor has negligible resistivit...
متن کاملA Coaxial Cable Fabry-Perot Interferometer for Sensing Applications
This paper reports a novel coaxial cable Fabry-Perot interferometer for sensing applications. The sensor is fabricated by drilling two holes half-way into a coaxial cable. The device physics was described. The temperature and strain responses of the sensor were tested. The measurement error was calculated and analyzed.
متن کاملTwo-slot coiled coaxial cable resonator: reaching critical coupling at a reduced number of coils.
This paper reports the experimental demonstration of a coiled coaxial cable resonator capable of meeting the critical coupling condition using a reduced number of coils relative to previously reported coiled resonators. By introducing a second slot along the length of the device, a two-slot coiled coaxial cable resonator was fabricated and critical coupling observed at 22 turns. An additional d...
متن کاملDevelopment of a Distributed Crack Sensor Using Coaxial Cable
Cracks, the important factor of structure failure, reflect structural damage directly. Thus, it is significant to realize distributed, real-time crack monitoring. To overcome the shortages of traditional crack detectors, such as the inconvenience of installation, vulnerability, and low measurement range, etc., an improved topology-based cable sensor with a shallow helical groove on the outside ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Korean Institute of Electromagnetic Engineering and Science
سال: 2020
ISSN: 1226-3133,2288-226X
DOI: 10.5515/kjkiees.2020.31.6.542