Analysis of hazardous chemicals by capillary electrophoresis.
نویسندگان
چکیده
منابع مشابه
A stability indicating capillary electrophoresis method for analysis of buserelin
A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...
متن کاملA stability indicating capillary electrophoresis method for analysis of buserelin
A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...
متن کاملAnalysis of RNA by capillary electrophoresis.
Analytical parameters known to be important for the separation of DNA by capillary electrophoresis, including gel polymer concentration, electrical field strength and temperature, were investigated and optimized for the analysis of RNA molecules from 100 to 2000 bases. Denaturation, essential to obtain uniform and identifiable peaks, was accomplished by heating the sample in 80% formamide prior...
متن کاملRNA structure analysis assisted by capillary electrophoresis.
Although most capillary electrophoresis (CE) applications in the nucleic acid field performed so far address DNA analysis, various RNA assays by CE have also been done. Both natural and synthetic RNAs have been examined to evaluate their quantities, sizes and interactions. In this report, we show a novel application of CE in RNA research for the analysis of RNA stable conformers. First, we pres...
متن کاملClinical analysis by microchip capillary electrophoresis.
Clinical analysis often requires rapid, automated, and high-throughput analytical systems. Microchip capillary electrophoresis (CE) has the potential to achieve very rapid analysis (typically seconds), easy integration of multiple analytical steps, and parallel operation. Although it is currently still in an early stage of development, there are already many reports in the literature describing...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 2001
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.50.721