Analysis of Failure Causes of Grounding Flat Steel for 110kV Transmission Tower

نویسندگان

چکیده

Abstract The corrosion causes of the grounded flat steel a 110kV transmission tower were experimentally analyzed by means macro testing, microstructure inspection, chemical composition analysis, product morphology and energy spectrum, galvanized layer thickness test, soil physical property analysis other test methods. results show that improper selection anti-corrosion process service environment alkaline high salt are main reasons for its fracture. It is proposed power grid equipment should not use grounding cold galvanizing process, inspection in Irrigation areas along Yellow River be strengthened.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

analysis of ruin probability for insurance companies using markov chain

در این پایان نامه نشان داده ایم که چگونه می توان مدل ریسک بیمه ای اسپیرر اندرسون را به کمک زنجیره های مارکوف تعریف کرد. سپس به کمک روش های آنالیز ماتریسی احتمال برشکستگی ، میزان مازاد در هنگام برشکستگی و میزان کسری بودجه در زمان وقوع برشکستگی را محاسبه کرده ایم. هدف ما در این پایان نامه بسیار محاسباتی و کاربردی تر از روش های است که در گذشته برای محاسبه این احتمال ارائه شده است. در ابتدا ما نشا...

15 صفحه اول

fabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

woman-defined identity: analysis of selected poems of adrienne rich

the current thesis is composed in five chapters in the following fashion: chapter two encompasses the applied framework of the project in details; the methodology of carl gustav jung to explain the process of individuation, the major archetypes and their attributes and his techniques to assess the mind’s strata are all explained. moreover, the austrian psychoanalysts, heinz kohut’s models of a...

Lightning Performance and its Prevention for Quadruple-circuit Transmission Line with 220kV/110kV Voltage in a Tower

According to the physical process of discharge development of insulator that is struck by lightning, the lightning flashover model for quadruple-circuit transmission line with dual voltage 220kV/110kV in same tower is established basing on EMTP. The actual evaluation index of lightning protection performance is adopted with the consideration of influence of system voltage. The characteristics o...

متن کامل

Causes of Catastrophic Failure of High Mn Steel Utilized as Crusher Overlaying Shields (TECHNICAL NOTE)

The secondary cone crusher's shields at Sarcheshmeh Copper Complex of Iran are made of Hadfield steel with a nominal composition of Fe-1.3 % C-12 % Mn. They have a cut-off in the shape of a cone with an upper end diameter of 80cm and an approximate lower end diameter of 200 cm whose main problem is an unexpected early failure under normal working condition. In this paper, the results of metallo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of physics

سال: 2022

ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']

DOI: https://doi.org/10.1088/1742-6596/2378/1/012031